Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › C4d Fragment, EIA

C4d Fragment, EIA: Quest Diagnostics test 4943

Quest Diagnostics test 4943, CPT 83520. Specimen: 1 mL plasma collected in an EDTA (lavender-top) tube.

C4d Fragment, EIA is Quest Diagnostics test code 4943, billed with CPT 83520. Specimen: 1 mL plasma collected in an EDTA (lavender-top) tube. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories, Labcorp, Michigan Medicine Laboratories (MLabs).
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code4943
CPT83520
LOINC—
Specimen1 mL plasma collected in an EDTA (lavender-top) tube
Minimum volume0.2 mL
ContainerTransport tube
Storage / transportFrozen

Methodology

Enzyme Immunoassay (EIA)

Stability

TemperaturePeriod
Room temperatureUnacceptable
Refrigerated4 hours
Frozen14 days

Causes for rejection

Hemolysis • Received room temperature • Received refrigerated

Reference range

0.9-8.0 mcg/mL

Assay category

This test was performed using a kit that has not been cleared or approved by the FDA. The analytical performance characteristics of this test have been determined by Quest Diagnostics. This test should not be used for diagnosis without confirmation by other medically established means.

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 83520

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation