Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › Multiple Sclerosis (MS) Differential Evaluation with Reflexes

Multiple Sclerosis (MS) Differential Evaluation with Reflexes: Quest Diagnostics test 18216

Quest Diagnostics test 18216, CPT 82607, 86038, 86052, 86235, 86362, 86431, 86618, 86790. Specimen: 11 mL serum collected in a red-top tube (no gel).

Multiple Sclerosis (MS) Differential Evaluation with Reflexes is Quest Diagnostics test code 18216, billed with CPT 82607, 86038, 86052, 86235, 86362, 86431, 86618, 86790. Specimen: 11 mL serum collected in a red-top tube (no gel). Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Labcorp, ARUP Laboratories, OHSU Laboratory Services, Allina Health Laboratory (Abbott Northwestern), Michigan Medicine Laboratories (MLabs).
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code18216
CPT86038, 86052, 86790, 86618, 86362, 86431, 86235 (x2), 82607
LOINC—
Specimen11 mL serum collected in a red-top tube (no gel)
Minimum volume4.7 mL
ContainerTransport tube(s)
Storage / transportRefrigerated (cold packs)

Also known as: Borrelia burgdorferi; FANA; Antibody Screen; Antinuclear; Fluorescent ANA; HAM/TSP; Hep-2; Progressive ANA; HTLV-1-associated myelopathy; HTLV-2; Aquaporin; Rheumatoid Factor; Multiple Sclerosis MIMIC; Devic’s Antibody; human T-cell leukemia virus; AQP4; Neuromyelitis Optica; MOG-IgG; NMO antibody; Optic Neuritis Antibody; Cobalamin; NMO-IgG; Transverse Myelitis Antibody; ADEM antibody; LETM antibody; Myelin oligodendrocyte glycoprotein; NMO Spectrum Disorder; NMOSD; MS; Cyanocobalamin; Tropical Spastic Paraparesis; SS-A & SS-B

Methodology

Cell-based Immunofluorescence Assay • Immunoassay (IA) • Immunoturbidimetric Assay • Immunofluorescence Assay (IFA) • Immunoblot (IB)

Collection instructions

Label the tubes according to your standard operating procedure, making sure that each tube has at least two unique patient identifiers. Draw 9 tubes, 11 mL serum in a red-top tube (no gel). Allow the blood to clot for at least 30 minutes, but not longer than 1 hour before centrifugation. Centrifuge each tube for 15 minutes at 1250 to 1600 RCF. Transfer serum to plastic screw-cap vial(s). The plastic screw-cap vial containing serum must be labeled with the specimen type. Place sample(s) on cold packs or in refrigerator. Sample is stable for 7 days at 2-8° C (refrigerated). Do not transport or store samples at room temperature.

Stability

TemperaturePeriod
Room temperatureUnacceptable
Refrigerated7 days
Frozen21 days

Causes for rejection

Hemolysis • Grossly lipemic • Grossly icteric • Visible particulate matter • Serum separator tube (SST) • Microbial contamination • Plasma

Reference range

See Laboratory Report

Notices

CPT Code is subject to a Medicare Limited Coverage Policy and may require a signed ABN when ordering.

Assay category

This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 82607, 86038, 86052

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation