Multiple Sclerosis (MS) Differential Evaluation with Reflexes: Quest Diagnostics test 18216
Quest Diagnostics test 18216, CPT 82607, 86038, 86052, 86235, 86362, 86431, 86618, 86790. Specimen: 11 mL serum collected in a red-top tube (no gel).
Also known as: Borrelia burgdorferi; FANA; Antibody Screen; Antinuclear; Fluorescent ANA; HAM/TSP; Hep-2; Progressive ANA; HTLV-1-associated myelopathy; HTLV-2; Aquaporin; Rheumatoid Factor; Multiple Sclerosis MIMIC; Devic’s Antibody; human T-cell leukemia virus; AQP4; Neuromyelitis Optica; MOG-IgG; NMO antibody; Optic Neuritis Antibody; Cobalamin; NMO-IgG; Transverse Myelitis Antibody; ADEM antibody; LETM antibody; Myelin oligodendrocyte glycoprotein; NMO Spectrum Disorder; NMOSD; MS; Cyanocobalamin; Tropical Spastic Paraparesis; SS-A & SS-B
Methodology
Cell-based Immunofluorescence Assay • Immunoassay (IA) • Immunoturbidimetric Assay • Immunofluorescence Assay (IFA) • Immunoblot (IB)
Collection instructions
Label the tubes according to your standard operating procedure, making sure that each tube has at least two unique patient identifiers. Draw 9 tubes, 11 mL serum in a red-top tube (no gel). Allow the blood to clot for at least 30 minutes, but not longer than 1 hour before centrifugation. Centrifuge each tube for 15 minutes at 1250 to 1600 RCF. Transfer serum to plastic screw-cap vial(s). The plastic screw-cap vial containing serum must be labeled with the specimen type. Place sample(s) on cold packs or in refrigerator. Sample is stable for 7 days at 2-8° C (refrigerated). Do not transport or store samples at room temperature.
Stability
| Temperature | Period |
|---|---|
| Room temperature | Unacceptable |
| Refrigerated | 7 days |
| Frozen | 21 days |
Causes for rejection
Hemolysis • Grossly lipemic • Grossly icteric • Visible particulate matter • Serum separator tube (SST) • Microbial contamination • Plasma
Reference range
See Laboratory Report
Notices
CPT Code is subject to a Medicare Limited Coverage Policy and may require a signed ABN when ordering.
Assay category
This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.
View this test on Quest Diagnostics's website → · Last checked 2026-11-29
Other tests billed with CPT 82607, 86038, 86052
- Anemia Profile B
- Cognitive Assessment Panel with Reflex to T4 Free
- Dementia Panel, Secondary Causes
- Long COVID Profile
- Micronutrient, Vitamin B12
- Micronutrients, B-Vitamin Panel
- Pernicious Anemia Diagnostic Panel
- Post COVID-19 Expanded Panel
- Post COVID-19 Panel
- Post-Bariatric Surgery Comprehensive Profile
- Post-Bariatric Surgery Micronutrient Profile
- Pre-Bariatric Surgery Comprehensive Profile
- Pre-Bariatric Surgery Micronutrient Profile
- Vitamin B 12
- Vitamin B 12 and Folate
- Vitamin B-12
- Vitamin B12
- Vitamin B12
- Vitamin B12
- Vitamin B12
- Vitamin B12 and Folates
- Vitamin B12 Deficiency Cascade
- Vitamin B12 w/reflex
- Vitamin B12 with Reflex to Methylmalonic Acid, Serum (Vitamin B12 Status)
- Anemia Profile B
- Vitamin B12
- Vitamin B12 and Folates
- ANA
- ANA 12 Plus Profile (RDL)
- ANA 12 Plus Profile, Do All (RDL)
Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation