Vitamin B12: Labcorp test 001503
Labcorp test 001503, CPT 82607. Specimen: Serum. Turnaround: Within 1 day.
Vitamin B12 is Labcorp test code 001503, billed with CPT 82607. Specimen: Serum. Turnaround time: Within 1 day. Performing laboratory: Labcorp, CLIA
34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories.
Test code001503
CPT82607
LOINC2132-9
SpecimenSerum
Volume1 mL
Minimum volume0.7 mL ( Note: This volume does not allow for repeat testing.)
ContainerGel-barrier tube (preferred) or red-top tube
Turnaround timeWithin 1 day
Storage / transportRoom temperature
Also known as: Cobalamin, True
Use
Detect B 12 deficiency as in pernicious anemia; diagnose folic acid deficiency; evaluate hypersegmentation of granulocyte nuclei; follow up MCV >100; diagnose macrocytic anemia; diagnose megaloblastic anemia; evaluate alcoholism, prenatal care; evaluate malabsorption, neurological disorders, or the elevation of B 12 as seen in liver cell damage or myeloid leukemia
Methodology
Electrochemiluminescence immunoassay (ECLIA)
Collection instructions
If a red-top tube is used, transfer separated serum to a plastic transport tube.
Stability
| Temperature | Period |
|---|
| Room temperature | 7 days |
| Refrigerated | 7 days |
| Frozen | 14 days |
| Freeze/thaw cycles | Stable x3 |
Patient preparation
Fasting specimen preferred; must draw before Schilling test, transfusions or B 12 therapy is started.
Causes for rejection
Citrate plasma specimen; improper labeling
Reference range
232−1245 pg/mL
Special instructions
This test may exhibit interference when sample is collected from a person who is consuming a supplement with a high dose of biotin (also termed as vitamin B7 or B8, vitamin H, or coenzyme R). It is recommended to ask all patients who may be indicated for this test about biotin supplementation. Patients should be cautioned to stop biotin consumption at least 72 hours prior to the collection of a sample.
Limitations
As with all tests containing monoclonal mouse antibodies, erroneous findings may be obtained from samples taken from patients who have been treated with monoclonal mouse antibodies or have received them for diagnostic purposes. In rare cases, interference due to extremely high titers of antibodies to streptavidin and ruthenium can occur. The test contains additives, which minimize these effects.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|
| 001503 | Vitamin B12 | pg/mL | 2132-9 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 82607
- Anemia Profile B
LabcorpTest code 042077CPT 82607, 82728, 82746, 83540, 83550, 85025, 85045Serum and whole bloodTAT Within 1 day
- Long COVID Profile
LabcorpTest code 165065CPT 80053, 81003, 82306, 82607, 82728, 84439, 84443, 85025, 86140Serum, urine, whole bloodTAT Within 1 day
- Post-Bariatric Surgery Comprehensive Profile
LabcorpTest code 259090CPT 80053, 80061, 82306, 82390, 82525, 82607, 82728, 82746, 83036, 83540, 83550, 83921, 83970, 84238, 84425, 84443, 84590, 84630, 85027Serum, whole blood, plasmaTAT 5 - 7 days
- Post-Bariatric Surgery Micronutrient Profile
LabcorpTest code 259129CPT 82306, 82310, 82390, 82525, 82607, 82728, 82746, 83540, 83550, 84238, 84425, 84590, 84630, 85025Serum, whole blood, plasmaTAT 3 - 5 days
- Pre-Bariatric Surgery Comprehensive Profile
LabcorpTest code 259141CPT 80053, 80061, 82306, 82390, 82525, 82607, 82728, 82746, 83036, 83540, 83550, 83921, 84425, 84443, 84466, 84590, 84630, 85027Serum, whole blood, plasmaTAT 5 - 7 days
- Pre-Bariatric Surgery Micronutrient Profile
LabcorpTest code 259104CPT 82306, 82310, 82390, 82525, 82607, 82728, 82746, 84425, 84630Serum, whole blood, plasmaTAT 2 - 4 days
- Vitamin B 12
ARUP LaboratoriesTest code 0070150CPT 82607Serum separator tube. Also acceptable: Green (sodium or lithium heparin).TAT Within 24 hours
- Vitamin B 12 and Folate
ARUP LaboratoriesTest code 0070160CPT 82607, 82746Serum separator tube. Also acceptable: Green (sodium or lithium heparin).TAT Within 24 hours
- Vitamin B12
Cleveland Clinic LaboratoriesTest code B12CPT 82607SerumTAT 8 hours
- Vitamin B12 and Folates
LabcorpTest code 000810CPT 82607, 82746SerumTAT Within 1 day
- Vitamin B12 Deficiency Cascade
LabcorpTest code 141503CPT 82607SerumTAT 1 - 2 days
- Vitamin B12 w/reflex
Cleveland Clinic LaboratoriesTest code B12RFXCPT 82607SerumTAT 8 hours
- Vitamin B12 with Reflex to Methylmalonic Acid, Serum (Vitamin B12 Status)
ARUP LaboratoriesTest code 0055662CPT 82607, 83921Plain red or serum separator tube. Also acceptable: Green (sodium or lithium hepTAT 1-5 days
- Anemia Profile B
LabcorpTest code 042077Women's HealthCPT 82607, 82728, 82746, 83540, 83550, 85025, 85045Serum and whole bloodTAT Within 1 day
- Vitamin B12
LabcorpTest code 001503Women's HealthCPT 82607SerumTAT Within 1 day
- Vitamin B12 and Folates
LabcorpTest code 000810Women's HealthCPT 82607, 82746SerumTAT Within 1 day
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code.
Submit your lab's test menu → Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation