Labcorp test 141503, CPT 82607. Specimen: Serum. Turnaround: 1 - 2 days.

Vitamin B12 Deficiency Cascade is Labcorp test code 141503, billed with CPT 82607. Specimen: Serum. Turnaround time: 1 - 2 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code141503
CPT82607
LOINC2132-9
SpecimenSerum
Volume3 mL
Minimum volume2 mL ( Note: This volume does not allow for repeat testing).
ContainerRed-top tube or gel-barrier tube
Turnaround time1 - 2 days
Storage / transportStore specimen at room temperature

Also known as: Megaloblastic Anemia Cascade; Pernicious Anemia Cascade

Test includes

Vitamin B12 testing is performed on all samples. If Vitamin B12 is <200 pg/mL: Intrinsic Factor Blocking Antibodies and Antiparietal Cell Antibody (APCA) will be performed at an additional charge. If Vitamin B12 is between 200 and 400 pg/mL: Methylmalonic Acid (MMA) will be performed at an additional charge. If Methylmalonic Acid (MMA) is >378 nmol/L: Intrinsic Factor Blocking Antibodies and Antiparietal Cell Antibody (APCA) will be performed at an additional charge.

Use

Diagnosis of Vitamin B12 Deficiency. Although often used as the first-line screening test for B12 deficiency, serum B12 measurement used in isolation has a generally poor sensitivity and specificity for detection of B12 deficiency.The National Health and Nutrition Examination Survey (NHANES) opted to use the combination of serum total vitamin B12 and methylmalonic acid (MMA) to monitor B12 status in the United States population. In the interest of economy, a number of groups have suggested the use of a sequential selection algorithm for the detection of B12 deficiency. In this approach, a second-line assay (in this case MMA) is performed only when the outcome of the first-line assay…

Collection instructions

If a red-top tube is used, transfer separated serum to a plastic transport tube.

Stability

TemperaturePeriod
Room temperature7 days
Refrigerated7 days
Frozen14 days
Freeze/thaw cyclesStable x3

Special instructions

This test may exhibit interference when sample is collected from a person who is consuming a supplement with a high dose of biotin (also termed as vitamin B7 or B8, vitamin H, or coenzyme R). It is recommended to ask all patients who may be indicated for this test about biotin supplementation. Patients should be cautioned to stop biotin consumption at least 72 hours prior to the collection of a sample.

Limitations

Ninety per cent of patients with pernicious anemia have gastric parietal cell antibodies, but specificity of this test is poor since they are also found in 15% of elderly subjects. If IFA results are negative but suspicion for pernicious anemia remains, an elevated serum gastrin level is consistent with the diagnosis. Mutations in the gene encoding intrinsic factor, can also lead to an inherited form of B12 malabsorption and deficiency, which resembles pernicious anemia, but without autoantibody involvement. In the presence of discordance between laboratory test result and strong clinical features of B12 deficiency, it remains important to proceed with treatment to avoid neurological…

LOINC map

Result codeResult nameUnitsResult LOINC
001503Vitamin B12pg/mL2132-9

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 82607

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation