Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › PrEP HIV-1/2 Antigen/Antibodies, 4th Generation, Reflex to Differentiation

PrEP HIV-1/2 Antigen/Antibodies, 4th Generation, Reflex to Differentiation: Quest Diagnostics test 13595

Quest Diagnostics test 13595, CPT 87389. Specimen: 2 mL serum.

PrEP HIV-1/2 Antigen/Antibodies, 4th Generation, Reflex to Differentiation is Quest Diagnostics test code 13595, billed with CPT 87389. Specimen: 2 mL serum. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Labcorp, OHSU Laboratory Services, Cleveland Clinic Laboratories, Allina Health Laboratory (Abbott Northwestern), Michigan Medicine Laboratories (MLabs).
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code13595
CPT87389
LOINC—
Specimen2 mL serum
Minimum volume1 mL
ContainerSerum separator tube (SST)
Storage / transportRoom temperature

Also known as: PrEP Fourth Generation HIV; PrEP 4th Generation HIV; PrEP Human Immunodeficiency Virus

Methodology

Immunoassay (IA)

Collection instructions

Serum: Collect in a serum separator tube or red-top tube (no gel). The tube should be centrifuged after clotting. Spun serum separator tubes may be submitted at room temperature or refrigerated unopened without transfer to a plastic screw-cap vial. Red-top tube (no gel) serum should be transferred to a plastic screw-cap vial and submitted for testing. Plasma: Collect in an EDTA (lavender-top) tube and centrifuge tube within 24 hours of collection. Transfer plasma to a plastic screw-cap vial, label as plasma, and submit for testing. Submitted tubes must be labeled with patient identifier and submitted only for HIV testing.

Stability

TemperaturePeriod
Room temperature72 hours
Refrigerated5 days
Frozen30 days

Causes for rejection

Gross hemolysis • Frozen specimens submitted in original collection container

Notices

CPT Code is subject to a Medicare Limited Coverage Policy and may require a signed ABN when ordering.

Alternative specimen(s)

Plasma collected in: EDTA (lavender-top) tube

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 87389

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation