Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › PrEP Use Only: HIV Antigen/Antibody and HIV RNA, Qualitative

PrEP Use Only: HIV Antigen/Antibody and HIV RNA, Qualitative: Labcorp test 083971

Labcorp test 083971, CPT 87389, 87535, 87538. Specimen: Serum. Turnaround: 3 - 5 days.

PrEP Use Only: HIV Antigen/Antibody and HIV RNA, Qualitative is Labcorp test code 083971, billed with CPT 87389, 87535, 87538. Specimen: Serum. Turnaround time: 3 - 5 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, Michigan Medicine Laboratories (MLabs), ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code083971
CPT87389; 87535; 87538
LOINC25835-0, 56888-1, 75622-1
SpecimenSerum
Volume2.5 mL
Minimum volume1.5 mL ( Note: This volume does not allow for repeat testing.)
ContainerGel-barrier tube
Turnaround time3 - 5 days
Storage / transportHIV Ag/Ab: gel barrier-tubes refrigerated up to 7 days HIV RNA: frozen up to 6 weeks or refrigerated up to 7 days

Also known as: HIV PrEP; pre-exposure prophylaxis screening for HIV

Test includes

HIV p24 antigen/antibody screen for HIV-1 antibody; HIV-2 antibody and HIV-1 p24 antigen by EIA; HIV-1/HIV-2 RNA testing by qualitative nucleic acid amplification (NAA). EIA positive specimens reflex to an HIV-1/HIV-2 antibody differentiation assay.

Use

PrEP use only: This profile includes HIV p24 antigen/antibody with reflex to antibody differentiation and HIV-1/2 qualitative RNA to support baseline assessment and monitoring of patients on PrEP for HIV infection.

Methodology

(1) HIV antigen/antibody enzyme immunoassay (EIA) screen for antibodies to HIV-1 and HIV-2 and HIV-1 p24 antigen: Reflex to supplementary differentiation assay (2) Qualitative nucleic acid amplification (NAA) for HIV-1 and HIV-2 RNA

Collection instructions

Collect using the usual blood collection technique. Do not freeze serum gel tubes; send to the lab refrigerated. Send frozen or refrigerated serum for RNA test in serum pour-off tube.

Stability

TemperaturePeriod
Refrigerated7 days
Frozen6 weeks

Causes for rejection

Hemolysis; lipemia; received outside of specimen and/or storage and/or labeling requirements; aliquot received for HIV Ag/Ab testing; specimen in expired transport or incorrect transport device; specimens with inappropriate source for test requested

Special instructions

PrEP use only . Contains CPT code modifier. This profile requires a dedicated, unopened, gel-barrier tube and a refrigerated or frozen serum pour-off tube. Tests included within this profile may exhibit interference when sample is collected from a person who is consuming a supplement with a high dose of biotin (also termed as vitamin B7 or B8, vitamin H, or coenzyme R). It is recommended to ask all patients who may be indicated for testing about biotin supplementation. Patients should be cautioned to stop biotin consumption at least 72 hours prior to the collection of a sample.

Limitations

HIV p24 antigen/antibody specimens with reactive results must be investigated by additional supplemental tests. A negative test for an individual does not preclude exposure to or infection with HIV-1 and/or HIV-2. Negative results can occur if the quantity of the marker present in the sample is too low for detection by the assay or if the marker is not present during the stage of disease in which a sample is collected.

LOINC map

Result codeResult nameUnitsResult LOINC
083903HIV Antibody/p24 Antigen56888-1
139826HIV-1 RNA25835-0

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 87389, 87535, 87538

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation