Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Bloodborne Pathogen Exposure Profile (HIV, HBV, HCV)

Bloodborne Pathogen Exposure Profile (HIV, HBV, HCV): Labcorp test 257524

Labcorp test 257524, CPT 86704, 86706, 86803, 87340, 87389. Specimen: Serum. Turnaround: 1 - 4 days.

Bloodborne Pathogen Exposure Profile (HIV, HBV, HCV) is Labcorp test code 257524, billed with CPT 86704, 86706, 86803, 87340, 87389. Specimen: Serum. Turnaround time: 1 - 4 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code257524
CPT86704; 86706; 86803; 87340; 87389
LOINC22322-2, 95235-8
SpecimenSerum
Volume5 mL
Minimum volume3 mL ( Note: This volume does not allow for repeat testing.)
ContainerGel-barrier tube
Turnaround time1 - 4 days

Also known as: BBP; Needlestick

Use

This profile is intended to support evaluation following potential exposure to bloodborne pathogens (e.g., needle stick and other sharps injuries, mucous membrane exposure and skin exposure). This profile includes assays for the detection of HBV, HCV and HIV.

Methodology

See individual test components.

Collection instructions

Usual blood collection technique

Stability

Test No. Sample Type Room Temperature Refrigerated Frozen Freeze/Thaw Cycles Serum 14 days 14 days 14 days Stable x3 Serum Antibody test: 24 hours PCR test: 24 hours Antibody test: 6 days PCR test: 72 hours Antibody test: 14 days PCR test: 6 weeks N/A Serum 48 hours 14 days 14 days Stable x5

Causes for rejection

Gross hemolysis; gross lipemia; samples containing particulate matter or exhibiting obvious microbial contamination

Special instructions

HIV p24 Antigen/Antibody With Reflex to Confirmation [083935] requires a dedicated, unopened , gel-barrier tube or red-top tube sent directly to the testing facility. If reflex test is performed, additional charges/CPT code(s) may apply. This test may exhibit interference when sample is collected from a person who is consuming a supplement with a high dose of biotin (also termed as vitamin B7 or B8, vitamin H, or coenzyme R). It is recommended to ask all patients who may be indicated for this test about biotin supplementation. Patients should be cautioned to stop biotin consumption at least 72 hours prior to the collection of a sample.

Limitations

Negative results do not rule out infection as analytes may be undetectable in early infection. The assays in this panel have not been FDA cleared or approved for the screening of blood or plasma donors, or for cadaveric specimens. Performance characteristics of some of the tests included in this panel have not been established for immunocompromised or immunosuppressed patients or patients less than 2 years of age.

LOINC map

Result codeResult nameUnitsResult LOINC
Bloodborne Pathogen Exposure006408Hep B Surface Ab, Qual22322-2
Bloodborne Pathogen Exposure006724HBV Interpretation95235-8

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 86704, 86706, 86803

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation