Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Michigan Medicine Laboratories (MLabs) › Paroxysmal Nocturnal Hemoglobinuria (PNH) Profile

Paroxysmal Nocturnal Hemoglobinuria (PNH) Profile: Michigan Medicine Laboratories (MLabs) test PNHRW

Michigan Medicine Laboratories (MLabs) test PNHRW, CPT 88184, 88185, 88188. Specimen: 2.6-10 ml ACD (solution A or B) whole blood. Turnaround: 8-48 hours.

Paroxysmal Nocturnal Hemoglobinuria (PNH) Profile is Michigan Medicine Laboratories (MLabs) test code PNHRW, billed with CPT 88184, 88185, 88188. Specimen: 2.6-10 ml ACD (solution A or B) whole blood. Turnaround time: 8-48 hours. Performing laboratory: Michigan Medicine Laboratories (MLabs), CLIA 23D0366712 (Ann Arbor, MI). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories, Labcorp.
LaboratoryMichigan Medicine Laboratories (MLabs)
CLIA number23D0366712
Test codePNHRW
CPT88184 x1, 88185 x9, 88188 X1
LOINC—
Specimen2.6-10 ml ACD (solution A or B) whole blood
Volume2.6-10 ml ACD (solution A or B) whole blood
Turnaround time8-48 hours
Storage / transportAmbient preferred, refrigerated acceptable

Use

Screening or confirming the diagnosis of Paroxysmal Nocturnal Hemoglobinuria (PNH). See http://www.pathology.med.umich.edu/handbook/Tables/Flow_Cytometry_Panel… for all Flow Cytometry Panels.

Collection instructions

Offsite Collection: The following information is required on a Hematopathology Consult requisition: 1. Relevant clinical history 2. Clinical or morphological findings and suspicions 3. Date and time of collection 4. Phone number and after hours pager number for ordering physician * Collect blood in a yellow top ACD A or B Vacutainer® tube. (EDTA is acceptable) * Send intact specimen at room temperature within 12 hours of collection. Specimen should arrive at the Flow Cytometry Lab within 72 hours of collection. * Do not freeze.

Reference range

RED BLOOD CELLS: PNH RBC-Partial Antigen Loss: 0.00-0.02% PNH RBC-Complete Antigen Loss: 0.00-0.01% PNH Granulocytes: 0.00-0.01% PNH Monocytes: 0.00-0.1% *Reference ranges may change over time. Please refer to the original patient report when evaluating results.*

Limitations

Requires an adequate number of viable cells for analysis. Improper collection or transport may result in decreased cell viability and cancellation of testing.

Section

Flow Cytometry

Performed

Monday-Saturday, 8:00am-4:30pm

NY State approved

No

Alternate specimens

Lavender EDTA Vacutainer® tubes are acceptable but not preferred.

Performing Laboratory

Hematopathology

View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29

Other tests billed with CPT 88184, 88185, 88188

Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation