Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Michigan Medicine Laboratories (MLabs) › Immunophenotypic Analysis, Leukemia / Lymphoma, Blood

Immunophenotypic Analysis, Leukemia / Lymphoma, Blood: Michigan Medicine Laboratories (MLabs) test LEUKB

Michigan Medicine Laboratories (MLabs) test LEUKB, CPT 88184, 88185, 88187, 88188, 88189. Specimen: Whole blood: (FULL) Yellow top ACD A or B Vacutainer® tube. Turnaround: 8 - 48 hrs.

Immunophenotypic Analysis, Leukemia / Lymphoma, Blood is Michigan Medicine Laboratories (MLabs) test code LEUKB, billed with CPT 88184, 88185, 88187, 88188, 88189. Specimen: Whole blood: (FULL) Yellow top ACD A or B Vacutainer® tube. Turnaround time: 8 - 48 hrs. Performing laboratory: Michigan Medicine Laboratories (MLabs), CLIA 23D0366712 (Ann Arbor, MI). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories, Labcorp.
LaboratoryMichigan Medicine Laboratories (MLabs)
CLIA number23D0366712
Test codeLEUKB
CPTFirst marker for all panels: 88184. TRIAGE: 88185 x9, 88188. ACUTE: 88185 x1-30, 88187/88188/88189. NONACUTE: 88185 x1-21, 88187/88188/88189. PCLO: 88185 x10, 88188
LOINC—
SpecimenWhole blood: (FULL) Yellow top ACD A or B Vacutainer® tube Whole blood: 7-10 ml Green top sodium heparin tube
VolumeWhole blood: (FULL) Yellow top ACD A or B Vacutainer® tube Whole blood: 7-10 ml Green top sodium heparin tube
Turnaround time8 - 48 hrs
Storage / transportRoom temperature

Also known as: Multiple Myeloma; Plasma Cell Panel (PCL); B and T Cell Typing for Lymphocytic Leukemias; Leukemia / Lymphoma Immunophenotyping; Lymphocyte Typing for Lymphoproliferative Disorders; Lymphocytic Leukemias, Acute and Chronic Subtyping; T and B Cell Typing for Lymphocytic Leukemias; Leukemias, Acute; Leukemias, Chronic; Chronic Lymphocytic Leukemia (CLL); Mixed Linage Acute Leukemia; Acute Lymphocytic Leukemia (ALL); Acute Myelogenous Leukemia (AML); Leukemia/Lymphoma, Uncertain Subtype; Leukemia/Lymphoma Workup; Prolymphocytic Leukemia (PLL); Mantle Cell Lymphoma/Leukemia (MCL); Hairy Cell Leukemia (HCL); Non-Hodgkin's Lymphoma; Follicular Lymphoma; Diffuse Large B-Cell Lymphoma (DLBCL); Leukemia/Lymphoma Acute Marker Panel; Leukemia/Lymphoma Nonacute Marker Panel; Leukemia/Lymphoma Combo Marker Panel; Panel 1: Stem Cell Neoplasm / Acute Leukemia; Panel 2: Mature Lymphoid Leukemia / Non-Hodgkin Lymphoma; Panel 4: Comprehensive Leukemia / Lymphoma

Use

Confirmation of diagnosis and immunophenotype in acute and chronic leukemias and lymphomas. See http://www.pathology.med.umich.edu/handbook/Tables/Flow_Cytometry_Panel… for all Flow Cytometry Panels.

Collection instructions

The following information is required on a Hematopathology Consult requisition: [list order =Y] Relevant clinical history Clinical or morphological findings and suspicions Date and time of collection Phone number and after hours pager number for ordering physician [/list] Collect blood in a green 7-10 ml sodium heparin Vacutainer® tube or yellow top ACD A or B Vacutainer® tube and transport at room temperature within 12 hours of collection. Include a copy of the patient's concurrently drawn White Blood Cell and Platelet counts, peripheral blood differential and an unstained peripheral blood smear, OR, concurrently collect a lavender EDTA Vacutainer® tube for a CBCD to be performed upon receipt of the specimen.

Reference range

LEUKB AND IMM reference ranges.docx *Pediatric Reference Ranges from Journal of Allergy and Clinical Immunology, vol. 112, No. 5, 11/2003 and studies performed at Michigan Medicine Flow Cytometry Laboratory. Absolute ranges are calculated utilizing absolute lymphocyte count ranges for the same age groups provided by the hematology laboratory.

Limitations

Requires an adequate number of viable cells for analysis. Improper collection or transport may result in decreased cell viability and cancellation of testing. Specimen transport should be arranged so that specimen will be received Monday-Friday and prior to noon on Saturday.

Section

Flow Cytometry

Performed

Monday - Friday, 8:00am - 4:30pm; Saturday 8:00am-4:30pm

NY State approved

No

Alternate specimens

Lavender EDTA Vacutainer® tubes are acceptable but not preferred.

Performing Laboratory

Hematopathology

View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29

Other tests billed with CPT 88184, 88185, 88187

Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation