Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › ARUP Laboratories › B-Lymphoblastic Leukemia (B-ALL) Minimum Residual Disease Detection by Flow Cytometry

B-Lymphoblastic Leukemia (B-ALL) Minimum Residual Disease Detection by Flow Cytometry: ARUP Laboratories test 3000724

ARUP Laboratories test 3000724, CPT 88184, 88185, 88187, 88188. Specimen: Bone marrow aspirate or whole blood: green (sodium heparin) or lavender (EDTA).. Turnaround: 1-3 days.

B-Lymphoblastic Leukemia (B-ALL) Minimum Residual Disease Detection by Flow Cytometry is ARUP Laboratories test code 3000724, billed with CPT 88184, 88185, 88187, 88188. Specimen: Bone marrow aspirate or whole blood: green (sodium heparin) or lavender (EDTA).. Turnaround time: 1-3 days. Performing laboratory: ARUP Laboratories, CLIA 46D0523979 (Salt Lake City, UT). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, Labcorp.
LaboratoryARUP Laboratories
CLIA number46D0523979
Test code3000724
CPT88184; 88185 each additional marker; 88187 or 88188.
LOINC19099-1, 45267-2
SpecimenBone marrow aspirate or whole blood: green (sodium heparin) or lavender (EDTA).
Turnaround time1-3 days
Storage / transportRoom temperature. Also acceptable: Refrigerated. Specimen should be received within 24 hours of collection for optimal cell viability.

Also known as: Acute Leukemia Follow up Phenotyping by Flow Cytometry; Follow-Up Phenotyping; Hematopoietic neoplasms monitoring; Leukemia/Lymphoma Evaluation Panel; Leukemia/Lymphoma Phenotyping, Comprehensive - Bone Marrow; Leukemia/Lymphoma Phenotyping, Comprehensive - Miscellaneous; Leukemia/Lymphoma Phenotyping, Comprehensive - Whole Blood

Use

Use to detect minimal residual disease (MRD) in patients of all ages previously diagnosed with B-ALL. The specific markers used and reported vary based on the specimen submitted and whether a Children's Oncology Group (COG) protocol is specified at the time of ordering. Orders for whole blood testing will be canceled if the patient is 31 years or older or if there is a prior history of COG whole blood testing. For more information, refer to Additional Technical Information.

Methodology

Flow Cytometry

Collection instructions

Transport 2 mL heparinized bone marrow aspirate (Min: 1.0 mL) OR 3 mL whole blood (Min: 1.0 mL)

Stability

Ambient: 48 hours; Refrigerated: 48 hours; Frozen: Unacceptable

Causes for rejection

Clotted or hemolyzed specimens.

Remarks

Provide specimen source, CBC, Wright-stained smear (if available), clinical history, differential diagnosis. Follow up: If previous leukemia/lymphoma phenotyping was performed at another lab, the outside flow cytometry report and histograms (if possible) should accompany the specimen.

Performed

Sun-Sat

Compliance Category

Analyte Specific Reagent (ASR)

New York DOH Approval Status

This test is not New York state approved. Due to short specimen stability it is recommended that this testing be submitted directly to a New York state-approved laboratory. Do not submit sample to ARUP.

LOINC map

Result codeResult nameUnitsResult LOINC
3000737Number of Markers19099-1
3000738B-All MRD Interpretation45267-2

View this test on ARUP Laboratories's website → · Last checked 2026-11-29

Other tests billed with CPT 88184, 88185, 88187

Search the National Lab Test Directory · All ARUP Laboratories tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation