Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Michigan Medicine Laboratories (MLabs) › PLA2R (Phospholipase A2 Receptor) Autoantibody

PLA2R (Phospholipase A2 Receptor) Autoantibody: Michigan Medicine Laboratories (MLabs) test PLA2R

Michigan Medicine Laboratories (MLabs) test PLA2R, CPT 83520. Specimen: 0.5 mL serum.

PLA2R (Phospholipase A2 Receptor) Autoantibody is Michigan Medicine Laboratories (MLabs) test code PLA2R, billed with CPT 83520. Specimen: 0.5 mL serum. Performing laboratory: Michigan Medicine Laboratories (MLabs), CLIA 23D0366712 (Ann Arbor, MI). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories, Labcorp, Quest Diagnostics.
LaboratoryMichigan Medicine Laboratories (MLabs)
CLIA number23D0366712
Test codePLA2R
CPT83520
LOINC—
Specimen0.5 mL serum
Volume0.5 mL serum
Storage / transportFreeze at -25 °C. Add-ons may be done to refrigerated samples up to 48 hours old.

Use

Primary membranous nephropathy is an autoimmune disease which demonstrates autoantibodies to the M-type phospholipase A2 receptor (PLA2R) in up to 70% of patients. Autoantibodies to PLA2R may be useful in distinguishing primary membranous nephropathy from secondary membranous nephropathy and other forms of glomerulonephritis. As such, testing for anti-PLA2R antibodies may be useful in patients with idiopathic nephrotic syndrome. In PLA2R antibody-positive patients, quantitative changes in the anti-PLA2R value generally precedes a change in clinical status with respect to clinical remission, relapse, or risk assessment after kidney transplantation.

Reference range

Negative: <14 RU/mL Borderline: 14 - 19 RU/mL Positive: >19 RU/mL

Section

Special Chemistry

Performed

One day weekly; Tuesday

NY State approved

No

Performing Laboratory

Immunology & Special Chemistry

View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29

Other tests billed with CPT 83520

Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation