Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Michigan Medicine Laboratories (MLabs) › Parietal Cell Antibody

Parietal Cell Antibody: Michigan Medicine Laboratories (MLabs) test PAC

Michigan Medicine Laboratories (MLabs) test PAC, CPT 86256. Specimen: 0.5 mL serum. Turnaround: 8 hours.

Parietal Cell Antibody is Michigan Medicine Laboratories (MLabs) test code PAC, billed with CPT 86256. Specimen: 0.5 mL serum. Turnaround time: 8 hours. Performing laboratory: Michigan Medicine Laboratories (MLabs), CLIA 23D0366712 (Ann Arbor, MI). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Allina Health Laboratory (Abbott Northwestern), Labcorp.
LaboratoryMichigan Medicine Laboratories (MLabs)
CLIA number23D0366712
Test codePAC
CPT86256
LOINC—
Specimen0.5 mL serum
Volume0.5 mL serum
Turnaround time8 hours

Also known as: Anti-parietal Cell Antibody

Use

Useful in the diagnosis of pernicious anemia in which approximately 80% of patients demonstrate antibodies. A positive test in the presence of a megaloblastic anemia makes pernicious anemia a probable diagnosis. A negative test will help differentiate pernicious anemia from other anemias and Whipple's disease. Rarely, antiparietal cell antibodies are found in patients with gastric ulcer, atrophic gastritis, chronic thyroiditis, iron deficiency anemia, juvenile diabetes mellitus, idiopathic Addison's disease, gastric carcinoma, and in the normal population.

Collection instructions

Collect specimen in SST tube. Centrifuge, aliquot serum into a plastic vial and refrigerate for up to 3 days. Specimen should be frozen if it's not going to be received in Immunology within 3 days of collection.

Reference range

Negative. Result is reported as Negative, 1:20, or >=1:80.

Limitations

The increasing incidence of the antibody with increasing patient age may reflect the increasing incidence of atrophic gastritis in the elderly. The antibody is found with increased frequency in relatives of patients with pernicious anemia.

Section

Immunology

Performed

Tuesday, Friday

NY State approved

No

Alternate specimens

Red top tube.

Performing Laboratory

Immunology & Special Chemistry

View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29

Other tests billed with CPT 86256

Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation