Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Michigan Medicine Laboratories (MLabs) › P2Y12 Platelet Function Test

P2Y12 Platelet Function Test: Michigan Medicine Laboratories (MLabs) test P2Y12

Michigan Medicine Laboratories (MLabs) test P2Y12, CPT 85576. Specimen: Full 2.7mL tube preferred, full 1.8mL tube is acceptable. Turnaround: 1 hour.

P2Y12 Platelet Function Test is Michigan Medicine Laboratories (MLabs) test code P2Y12, billed with CPT 85576. Specimen: Full 2.7mL tube preferred, full 1.8mL tube is acceptable. Turnaround time: 1 hour. Performing laboratory: Michigan Medicine Laboratories (MLabs), CLIA 23D0366712 (Ann Arbor, MI). Other labs in the directory with tests billed under the same CPT: Allina Health Laboratory (Abbott Northwestern), Cleveland Clinic Laboratories, ARUP Laboratories, OHSU Laboratory Services.
LaboratoryMichigan Medicine Laboratories (MLabs)
CLIA number23D0366712
Test codeP2Y12
CPT85576
LOINC—
SpecimenFull 2.7mL tube preferred, full 1.8mL tube is acceptable
VolumeFull 2.7mL tube preferred, full 1.8mL tube is acceptable
Turnaround time1 hour

Also known as: Ticagrelor Platelet Function Test; Ticlopidine (Ticlid) Platelet Function Test; Plavix Platelet Function Test; Verify Now P2Y12; P2Y12 Platelet Function Test; Clopidogrel (Plavix) Platelet Function Test; Thienopyridine Platelet Function Test; Prasurgrel Platelet Function Test; Brilinta (Ticagrelor)

Use

To determine the degree of platelet inhibition from the use of P2Y12 inhibition drug therapies known as thienopyridines. These include Clopidogrel (Plavix), Prasugrel, Ticlopidine (Ticlid), and Ticagrelor.

Collection instructions

Collect specimen in a 2.7 mL blue top (citrate 3.2%) tube using a 21 gauge or larger needle. Mix by inversion. Do not centrifuge. Whole blood specimen should arrive at lab within 3 hours of collection; transport at room temperature. Collection of the blood through lines that have been previously flushed with heparin should be avoided. If the blood must be drawn through a VAD (vascular access device), the line should be flushed with 5 mL of saline and the first 5 mL of blood or six dead space volumes of the VAD discarded.

Reference range

180 - 376 PRU. Values less than 180 PRU may be evidence of a P2Y12 inhibitor effect.

Limitations

Platelet counts less than 119K or more than 502K, and Hematocrit values less than 33% or greater than 52% can interfere with testing and valid results may not be obtained. The P2Y12 Platelet Function assay is not intended for use with inherited platelet disorders such as von Willebrand Factor Deficiency, Glanzmann Thrombasthenia and Bernard-Soulier Syndrome.

Section

Coagulation

Performed

Daily, 24 hours

Contraindications

Patients who have been administered glycoprotein IIb/IIIa inhibitors tirofiban (Aggrastat) or eptifibatide (Integrilin) within the last 2 days or abciximab (ReoPro) within the last 2 weeks should not be tested.

NY State approved

No

Performing Laboratory

Clinical Core Laboratory

View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29

Other tests billed with CPT 85576

Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation