Sound Lab Consultants › National Lab Test Directory › Michigan Medicine Laboratories (MLabs) › Aspirin Platelet Function Test

Aspirin Platelet Function Test: Michigan Medicine Laboratories (MLabs) test ASPFT

Michigan Medicine Laboratories (MLabs) test ASPFT, CPT 85576. Specimen: Full 2.7mL tube preferred, full 1.8mL tube is acceptable. Turnaround: 1 hour.

Aspirin Platelet Function Test is Michigan Medicine Laboratories (MLabs) test code ASPFT, billed with CPT 85576. Specimen: Full 2.7mL tube preferred, full 1.8mL tube is acceptable. Turnaround time: 1 hour. Performing laboratory: Michigan Medicine Laboratories (MLabs), CLIA 23D0366712 (Ann Arbor, MI). Other labs in the directory with tests billed under the same CPT: Allina Health Laboratory (Abbott Northwestern), Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryMichigan Medicine Laboratories (MLabs)
CLIA number23D0366712
Test codeASPFT
CPT85576
LOINC—
SpecimenFull 2.7mL tube preferred, full 1.8mL tube is acceptable
VolumeFull 2.7mL tube preferred, full 1.8mL tube is acceptable
Turnaround time1 hour

Also known as: Aspirin Platelet Function Test; Verify Now Aspirin; Aspirin Response; Aspirin Resistance

Use

Aid in the detection of platelet inhibition due to aspirin therapy.

Collection instructions

Collect specimen in a 2.7 mL blue top (citrate 3.2%) tube using a 21 gauge or larger needle. Mix by inversion. Do not centrifuge. Whole blood specimen should arrive at lab within 3 hours of collection; transport at room temperature. Collection of the blood through lines that have been previously flushed with heparin should be avoided. If the blood must be drawn through a VAD (vascular access device), the line should be flushed with 5 mL of saline and the first 5 mL of blood or six dead space volumes of the VAD discarded.

Reference range

Test results are reported in Aspirin Reaction Units (ARU). Therapeutic range for effective platelet inhibition for patients on an aspirin regimen is 350-549 ARU. Values of 550-700 ARU are seen in patients not on aspirin therapy or where therapy is not effectively inhibiting platelet function.

Limitations

Glycoprotein IIb/IIIa inhibitors (tirofiban/Aggrastat®, eptifibatide/Integrilin®, abciximab/ReoPro®), dipyridamole, clopidogrel, or non-steroidal anti-inflammatory drugs (NSAIDS) that inhibit COX-1 and/or COX-1, COX-2 enzymes (ibuprofen, naproxen, diclofenac, indomethacin, and piroxicam) have been documented to inhibit platelet function. NSAIDS taken within the last 24 hours may result in decreased ARU values; however, if an NSAID is ingested at the same time as aspirin, this may result in a higher ARU than with aspirin alone. Platelet counts less than 92K , and Hematocrit values less than 29% or greater than 56% can interfere with testing and valid results may not be obtained. The Aspirin…

Section

Coagulation

Performed

Daily, 24 hours

Contraindications

Patients who have been administered glycoprotein IIb/IIIa inhibitors tirofiban (Aggrastat) or eptifibatide (Integrilin) within the last 2 days or abciximab (ReoPro) within the last 2 weeks should not be tested.

NY State approved

No

Performing Laboratory

Clinical Core Laboratory

View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29

Other tests billed with CPT 85576

Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.