Allina Health Laboratory (Abbott Northwestern) test 8816, CPT 85576. Specimen: Whole blood - P2Y12 collection kit. Turnaround: 1 hour.

P2Y12 inhibition is Allina Health Laboratory (Abbott Northwestern) test code 8816, billed with CPT 85576. Specimen: Whole blood - P2Y12 collection kit. Turnaround time: 1 hour. Performing laboratory: Allina Health Laboratory (Abbott Northwestern), CLIA 24D0401558 (Minneapolis, MN). Other labs in the directory with tests billed under the same CPT: Michigan Medicine Laboratories (MLabs), Cleveland Clinic Laboratories, ARUP Laboratories, OHSU Laboratory Services.
LaboratoryAllina Health Laboratory (Abbott Northwestern)
CLIA number24D0401558
Test code8816
CPT85576
LOINC—
SpecimenWhole blood - P2Y12 collection kit
ContainerP2Y12 collection kit
Turnaround time1 hour

Also known as: Clopidogrel (Plavix); Platelet Inhibition; VerifyNow

Methodology

The VerifyNow point-of-care device is available for monitoring patients on anti-P2Y12 therapy (clopidogrel and prasugrel). The extent of ADP-induced platelet aggregation is recorded as the Platelet Reactivity Unit (PRU) value, which is diminished by thienopyridine agents that block the P2Y12 ADP receptor.

Collection instructions

Direct venipuncture collection (No Syringe) Using a 21-gauge needle or larger, collect tubes in the following order : One (1) waste clear top Vacutainer tube - 3 mL draw (discard) Three (3) blue Greiner tubes - These are partial fill 2 mL draw tubes. Fill exactly to the black arrow on the tube; do not over or under fill. One (1) lavender top tube Immediately following collection, thoroughly mix each sample by gently inverting each tube 5 times to prevent clotting Patient labels should be applied to the three (3) blue Greiner tubes and the one (1) lavender tube. The waste tube does not need to be labeled and can be discarded. Additional tubes may be collected with this draw in between the blue tubes and EDTA tube following order of draw protocol. Direct venipuncture collection (Syringe) Using a 21-gauge needle or larger, collect 3 mL of blood in the first syringe and discard Using a second syringe fill the tubes in the following order: Three (3) blue Greiner tubes - These are partial fill 2 mL draw tubes. Fill exactly to the black arrow on the tube; do not over or under fill. One (1) lavender top tube Immediately following collection, thoroughly mix each sample by gently inverting each tube 5 times to prevent clotting Additional tubes may be collected with this draw in between the blue tubes and EDTA tube following order of draw protocol. Line draw collection Discard the first 5 mL of blood from the line, because of this step the clear top waste tube is not necessary and may be discarded. Ensure the catheter is free of clots. Immediately transfer blood in the following order : Three (3) blue Greiner tubes - These are partial fill 2 mL draw tubes. Fill exactly to the black arrow on the tube; do not over or under fill. One (1) lavender top tube Immediately following addition to the tubes, thoroughly mix each sample by gently inverting each tube 5 times to prevent clotting Additional tubes may be collected with this draw in between the blue tubes and EDTA tube following order of draw protocol.

Stability

TIME SENSITIVE - Send by STAT courier Ambient - 4 hours Hospital Draw - hand deliver to Lab; do not send thru Pneumatic Tube System (PTS).

Causes for rejection

Improper labeling (unlabeled or mislabeled) Improper anticoagulant Improperly filled tube Hemolysis Clotted specimen Delay in transport Improper storage/transport temperature

Reference range

P2Y12 reaction units (PRU): Patients on P2Y12 Inhibition therapy : <208 Patients not on P2Y12 Inhibitor medications: 180 - 376

Performed

Daily - 24 hours

Abbreviation

P2Y

Order number

LAB8816

Transport container

Aspirin therapy and P2Y12 collection kit/tubes

Performing Laboratory

AHL - Coagulation: W Available at the Central Laboratory and Mercy and United hospitals.

View this test on Allina Health Laboratory (Abbott Northwestern)'s website → · Last checked 2026-11-29

Other tests billed with CPT 85576

Search the National Lab Test Directory · All Allina Health Laboratory (Abbott Northwestern) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation