Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Michigan Medicine Laboratories (MLabs) › HPV DNA Profile, Patient-Collect Vaginal Swab

HPV DNA Profile, Patient-Collect Vaginal Swab: Michigan Medicine Laboratories (MLabs) test HPVSC

Michigan Medicine Laboratories (MLabs) test HPVSC, CPT 87626. Specimen: 3 mL PreservCyt liquid. Turnaround: 24-72 hours.

HPV DNA Profile, Patient-Collect Vaginal Swab is Michigan Medicine Laboratories (MLabs) test code HPVSC, billed with CPT 87626. Specimen: 3 mL PreservCyt liquid. Turnaround time: 24-72 hours. Performing laboratory: Michigan Medicine Laboratories (MLabs), CLIA 23D0366712 (Ann Arbor, MI). Other labs in the directory with tests billed under the same CPT: Labcorp, Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryMichigan Medicine Laboratories (MLabs)
CLIA number23D0366712
Test codeHPVSC
CPT87626
LOINC—
Specimen3 mL PreservCyt liquid
Volume3 mL PreservCyt liquid
Turnaround time24-72 hours

Use

Cobas® HPV for use on the cobas® 6800 System (cobas® HPV) is a qualitative in vitro test for the detection of high-risk Human Papillomavirus . This test detects the high-risk HPV types 16, 18, 31, 33, 35, 39, 45, 51, 52, 56, 58, 59, 66, and 68. Self-collected vaginal specimens, obtained in a healthcare setting, can be tested as an alternative specimen type when cervical sampling is either contraindicated or cervical samples otherwise cannot be obtained. Cobas® HPV is indicated for use for routine cervical cancer screening as per professional medical guidelines, including triage of ASC-US cytology, co-testing (or adjunctive screen) with cytology, and HPV primary screening of individuals with…

Reference range

Negative for HPV High Risk Profile DNA; Type 16: not detected; Type 18: not detected; Other High Risk Types: not detected.

Limitations

Products containing carbomer(s), including vaginal lubricants, creams and gels may interfere with the test and should not be used during or prior to collecting cervical specimens. Use of over-the-counter products Replens™, RepHresh™ Vaginal Gel and RepHresh™ Clean Balance™ Kit has been associated with false-negative results. Use of Metronidazole Vaginal Gel has been associated with false-negative results. Significant amounts of blood in the ThinPrep vials may cause invalid results. A negative high-risk HPV result does not exclude the possibility of future cytologic HSIL or underlying CIN2-3 or cancer. The assay does not test for all HPV types known to infect anogenital tissue or for low…

Section

Molecular Microbiology

Performed

Monday - Friday

NY State approved

No

Performing Laboratory

Microbiology

View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29

Other tests billed with CPT 87626

Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation