Sound Lab Consultants › National Lab Test Directory › Labcorp › Human Papillomavirus (HPV) High-risk (Cobas®) With HPV 16 and 18, Rectal Source

Human Papillomavirus (HPV) High-risk (Cobas®) With HPV 16 and 18, Rectal Source: Labcorp test 508005

Labcorp test 508005, CPT 87626. Specimen: Rectal swab. Turnaround: 4 - 6 days.

Human Papillomavirus (HPV) High-risk (Cobas®) With HPV 16 and 18, Rectal Source is Labcorp test code 508005, billed with CPT 87626. Specimen: Rectal swab. Turnaround time: 4 - 6 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, Michigan Medicine Laboratories (MLabs), ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code508005
CPT87626
LOINC77376-2, 77394-5, 77395-2, 77396-0
SpecimenRectal swab
Volume2 mL
Minimum volume1 mL
ContainerThinPrep® vial only
Turnaround time4 - 6 days
Storage / transportRoom temperature

Use

Specifically identifies types HPV 16 and HPV 18 while concurrently detecting the rest of the high-risk types: 31, 33, 35, 39, 45, 51, 52, 56, 58, 59, 66, and 68, without further specific differentiation.

Methodology

Nucleic acid amplification (NAA)

Collection instructions

An anal-rectal cytology specimen is collected using a Dacron swab (for example: AMD-Ritmed Company Catalog N° 4001D, LabCorp N° 19762). Moisten the swab in tap water and insert as far as possible into the anal canal. Slowly rotate the swab in one direction with gentle pressure on the walls as the swab is slowly being withdrawn. Care should be taken to ensure the transition zone is sampled. Vigorously rotate the swab in the PreservCyt® solution 10 times while pushing against the wall of the ThinPrep® vial. Swirl the swab vigorously to release additional material. Discard the swab. Tighten the cap on the ThinPrep® container so that the torque line on the cap passes the torque line on the vial.

Causes for rejection

Improper collection or inadequate specimen; improperly labeled; specimen more than six months old in ThinPrep® vial; frozen specimens; specimen leaked in transit; quantity not sufficient for analysis; name discrepancies; excessively bloody specimens.

Limitations

Detection of HPV is dependent on the number of copies present in the specimen and may be affected by specimen collection methods, patient factors, stage of infection, and the presence of interfering substances.

LOINC map

Result codeResult nameUnitsResult LOINC
508006HPV other hr types77394-5
508007HPV 1677396-0
508008HPV 1877395-2

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 87626

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation