Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Self-Collection in Office or Patient Service Center, High Risk Human Papillomavirus (HPV) With Genotyping, Vaginal Swab

Self-Collection in Office or Patient Service Center, High Risk Human Papillomavirus (HPV) With Genotyping, Vaginal Swab: Labcorp test 507401

Labcorp test 507401, CPT 87626. Specimen: Vaginal swab collected with Copan FLOQSwab 552C.RM. Turnaround: 2 - 4 days.

Self-Collection in Office or Patient Service Center, High Risk Human Papillomavirus (HPV) With Genotyping, Vaginal Swab is Labcorp test code 507401, billed with CPT 87626. Specimen: Vaginal swab collected with Copan FLOQSwab 552C.RM. Turnaround time: 2 - 4 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, Michigan Medicine Laboratories (MLabs), ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code507401
CPT87626
LOINC11502-2, 61372-9, 61373-7, 77375-4, 77378-8, 8251-1
SpecimenVaginal swab collected with Copan FLOQSwab 552C.RM
Volume2 mL
Minimum volume1 mL ( Note : This volume does not allow for repeat testing.)
ContainerThinPrep® vial
Turnaround time2 - 4 days
Storage / transportMaintain liquid-based cytology specimens at room temperature.

Use

This test detects 14 High Risk HPV types in self-collected vaginal swabs processed into ThinPrep® vials. HPV 16 and HPV 18 are specifically identified, whereas the other 12 High Risk types (HPV 31, 33, 35, 39, 45, 51, 52, 56, 58, 59, 66 and 68) are reported in a pool.

Methodology

Nucleic acid amplification (NAA)

Collection instructions

The vaginal swab is collected using the Copan FLOQSwab 552C.RM and placed into a ThinPrep® vial containing PreservCyt solution. Patient Self Collection: 1. Patient should wash hands with soap and water prior to collecting the specimen. 2. Twist and pull cap to remove the FLOQSwab from the plastic sleeve. 3. Hold the FLOQSwab at the red mark. 4. Standing in a comfortable position, use the free hand to spread the skin of the vaginal opening, while carefully inserting the swab up to the red mark. 5. Gently rotate the swab for 10-30 seconds. 6. Place the swab back into the tube until you hear a CLICK. After collection, hand the swab to a health care professional for processing. Wash hands with soap and water. Healthcare Professional FLOQSwab Processing: 1. Handle the collected sample with care. 2. Carefully uncap the ThinPrep® vial and place it on a stable, flat surface. 3. Slowly pull the FLOQSwab cap off to remove the swab from the tube. Minimize touching the inner walls of the tube as you remove the FLOQSwab. 4. Hold the vial with one hand then with the other hand place the FLOQSwab tip into the vial until the FLOQSwab tip is fully immersed in the medium and touching the bottom of the vial. 5. Holding onto the vial, swirl the FLOQSwab along the inner vial wall for 20 seconds while ensuring the swab remains immersed in the medium. Be careful not to splash. 6. Carefully draw the FLOQSwab up along the inner vial wall until the tip is no longer immersed in the medium. Hold the tip against the inner vial wall to drain fluid off of the swab. Place the FLOQSwab into the tube and discard. 7. Re-cap the vial and tighten until the lines on the cap and vial meet or slightly overlap to prevent leakage. Store upright.

Stability

TemperaturePeriod
Room temperature30 days (stability provided by manufacturer or literature reference)
Refrigerated30 days (stability provided by manufacturer or literature reference)
FrozenNot acceptable

Patient preparation

In the three days prior to self-collection of a vaginal sample, use of vaginal ovules, creams or washes, vaginal contraceptives or condoms should be avoided. In the two days prior to self-collection of a vaginal sample, sexual intercourse and ultrasound scans or gynecological examinations should be abstained from.

Causes for rejection

Improper collection; inadequate specimen; improper labeling; specimen more than one month old in ThinPrep® vial; frozen specimen; specimen leaked in transit; quantity not sufficient for analysis; name discrepancies; non-vaginal source submitted; specimen submitted in SurePath™ vial; excessively bloody specimens; ThinPrep® vial containing the vaginal swab

Special instructions

The appropriate collection for this test requires a Copan FLOQSwab 552C.RM and a Thinprep® vial. These products are available as a kit using PeopleSoft No. 144747.

Limitations

Specimen collection during the menstrual cycle has not been evaluated. Results of this test should only be interpreted in conjunction with information available from clinical evaluation of the patient and patient history. The cobas® HPV Test has been validated for use with vaginal specimens collected with Copan FLOQSwabs® 552C.RM and suspended in PreserCyt® Solution. Assay performance has not been validated for use with other collection media and/or collection devices. Use of other collection media and/or collection devices may lead to false positive, false negative or invalid results. Detection of high-risk HPV is dependent on the number of copies present in the specimen and may be…

LOINC map

Result codeResult nameUnitsResult LOINC
507402HPV, Other HR Types77375-4
507403HPV 1661372-9
507404HPV 1861373-7
507406Additional Information:8251-1
019054PDF11502-2

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 87626

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.