Michigan Medicine Laboratories (MLabs) test APCR, CPT 85307. Specimen: Full 2.7 mL tube or 1 mL plasma aliquot. Turnaround: 1 hour.

Activated Protein C Resistance is Michigan Medicine Laboratories (MLabs) test code APCR, billed with CPT 85307. Specimen: Full 2.7 mL tube or 1 mL plasma aliquot. Turnaround time: 1 hour. Performing laboratory: Michigan Medicine Laboratories (MLabs), CLIA 23D0366712 (Ann Arbor, MI). Other labs in the directory with tests billed under the same CPT: Labcorp, Quest Diagnostics, ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryMichigan Medicine Laboratories (MLabs)
CLIA number23D0366712
Test codeAPCR
CPT85307
LOINC—
SpecimenFull 2.7 mL tube or 1 mL plasma aliquot
VolumeFull 2.7 mL tube or 1 mL plasma aliquot
Turnaround time1 hour
Storage / transportRoom temperature for whole blood or frozen aliquot of citrated plasma.

Also known as: APC Resistance; Factor V Leiden Mutation Screen; Protein C Resistance, Activated; Factor 5 Leiden Mutation Screen; APCRV

Use

Activated Protein C Resistance is associated with a point mutation in the Factor V gene. This mutation slows the inactivation of factor Va by APC causing a hypercoagulable state.

Collection instructions

Collect specimen in a blue top (citrate 3.2%) tube. Mix by inversion. Specimen should arrive at lab within 3 hours of collection; transport at room temperature. Alternatively, centrifuge, aliquot plasma into a plastic vial, and freeze the specimen within 4 hours of collection. Transport frozen specimen on dry ice. Collection of the blood through lines that have been previously flushed with heparin should be avoided. If the blood must be drawn through a VAD (vascular access device), the line should be flushed with 5 mL of saline and the first 5 mL of blood or six dead space volumes of the VAD discarded.

Reference range

Ratio greater than or equal to 1.8

Limitations

Initial oral anticoagulant treatment before stabilization and levels of Protein C below 50% may give low APCR ratios.

Section

Coagulation

Performed

Wednesday

Contraindications

This test is not indicated for inpatient evaluation of acute thrombosis.

NY State approved

No

Performing Laboratory

Clinical Core Laboratory

View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29

Other tests billed with CPT 85307

Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation