Activated Protein C Resistance (APCR): Labcorp test 117762
Labcorp test 117762, CPT 85307. Specimen: Plasma, frozen. Turnaround: 2 - 3 days.
Also known as: APCR
Use
This test screens for the factor V Leiden gene mutation and other causes of activated protein C resistance.
Methodology
This assay measures the effect of adding aPC on the activated partial thromboplastin time (aPTT) of the patient sample.An aPTT is performed twice, once with and again without added aPC. The ratio of the two clotting times is reported. The patient sample is diluted with factor V-deficient plasma. This serves to correct for any factor deficiencies in the patient sample and allows the test to be used for patients on oral anticoagulants. The reaction mixture also contains a heparin neutralizer to allow this test to be performed on patients receiving heparin therapy. This assay employs predilution of patient plasma in factor V-deficient plasma, enhancing sensitivity and specificity for factor…
Collection instructions
Citrated plasma samples should be collected by double centrifugation. Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples, except when using a winged blood collection device (ie, "butterfly"), in which case a discard tube should be used. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge for 10 minutes and carefully remove / 3 of the plasma using a plastic transfer pipette, being careful not to disturb the cells. Deliver to a plastic transport tube, cap, and recentrifuge for 10 minutes. Use a second plastic pipette to remove the plasma, staying clear of the platelets at the bottom of the tube. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
Stability
| Temperature | Period |
|---|---|
| Frozen | 28 days |
| Freeze/thaw cycles | Stable x3 |
Patient preparation
Do not draw from an arm with a heparin lock or heparinized catheter. Ideally, the patient should not be on anticoagulant therapy. Avoid warfarin (Coumadin®) therapy for two weeks prior to the test and heparin (direct Xa and thrombin inhibitor therapies) for about three days prior to testing.
Causes for rejection
Gross hemolysis; clotted specimen; frozen specimen thawed in transit; tubes <90% full; improper labeling; specimen collected in tube other than 3.2% citrate
Special instructions
If the patient's hematocrit exceeds 55%, the volume of citrate in the collection tube must be adjusted. Refer to Coagulation Collection Procedures for directions.
Limitations
A low APCR ratio in the absence of factor V Leiden most commonly reflects acquired or non-Leiden influences on the protein C pathway. These include antiphospholipid antibodies, particularly lupus anticoagulant, which can directly induce an acquired APCR phenotype, as well as autoantibodies against protein S that impair the APC cofactor function. In addition, elevated procoagulant factor levels, especially factor VIII (and to a lesser extent factors II, IX and X), reduce APC sensitivity and are a recognized mechanism of acquired resistance. Physiologic or hormonal states such as pregnancy and estrogen exposure (e.g., oral contraceptives) can also produce APCR through shifts in coagulation…
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 117763 | Act.Prt.C Resist. | ratio | 13590-5 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 85307
- APC Resistance
- APC Resistance
- APC Resistance with Reflex to Factor V Leiden (Change effective as of 01/19/27: Refer to 3021570 in the January Hotline)
- Hypercoagulation Diagnostic Interpretive Panel
- Thrombotic Risk Assessment
- Thrombotic Risk Reflex Panel
- Thrombotic Risk, Congenital
- Thrombotic Risk, Congenital (Extended)
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.