Activated Protein C-Resistance: Quest Diagnostics test 22
Quest Diagnostics test 22, CPT 85307. Specimen: 2 mL frozen platelet-poor citrated plasma collected in a 3.2% sodium citrate (light-blue-top) tube.
Activated Protein C-Resistance is Quest Diagnostics test code 22, billed with CPT 85307. Specimen: 2 mL frozen platelet-poor citrated plasma collected in a 3.2% sodium citrate (light-blue-top) tube. Performing laboratory: Quest Diagnostics, CLIA
49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Labcorp, Cleveland Clinic Laboratories, ARUP Laboratories.
Test code22
CPT85307
LOINC—
Specimen2 mL frozen platelet-poor citrated plasma collected in a 3.2% sodium citrate (light-blue-top) tube
Minimum volume1 mL
ContainerTransport tube
Storage / transportFrozen
Also known as: APC Resistance; APCR
Methodology
RVVT-based Assay (Clot-based)
Collection instructions
Platelet-poor plasma: Centrifuge light blue-top tube for 15 minutes at approximately 1500 g within 60 minutes of collection. Using a plastic pipette, remove plasma, taking care to avoid the WBC/platelet buffy layer and place into a plastic vial. Centrifuge a second time and transfer platelet-poor plasma into a new plastic vial. Plasma must be free of platelets (<10,000/mcL). Freeze immediately and ship on dry ice.
Stability
| Temperature | Period |
|---|
| Room temperature | Unacceptable |
| Refrigerated | Unacceptable |
| Frozen | 60 days |
Causes for rejection
Gross hemolysis • Clotted specimen • Serum
Reference range
≥2.1 Ratio
View this test on Quest Diagnostics's website → · Last checked 2026-11-29
Other tests billed with CPT 85307
- Activated Protein C Resistance (APCR)
LabcorpTest code 117762CPT 85307Plasma, frozenTAT 2 - 3 days
- Activated Protein C Resistance with Reflex to Factor V (Leiden) Mutation
Quest DiagnosticsTest code 19704CPT 853072 mL frozen platelet-poor citrated plasma collected in a 3.2% sodium citrate (li
- APC Resistance
Cleveland Clinic LaboratoriesTest code APCCPT 85307PlasmaTAT 1 - 3 days
- APC Resistance
ARUP LaboratoriesTest code 0030127CPT 85307Lt. blue (sodium citrate). Refer to Specimen Handling at aruplab.com for hemostaTAT 1-4 days
- APC Resistance with Reflex to Factor V Leiden (Change effective as of 01/19/27: Refer to 3021570 in the January Hotline)
ARUP LaboratoriesTest code 0030192CPT 81241, 85307Light blue (sodium citrate) AND lavender (EDTA), pink (K2EDTA), or yellow (ACD sTAT 1-5 days
- Hypercoagulation Diagnostic Interpretive Panel
Cleveland Clinic LaboratoriesTest code HYPERCPT 81240, 85240, 85300, 85303, 85307, 85384, 85390, 85520, 85598, 85610, 85670, 85730, 85732, 86140, 86146, 86147SerumTAT 3 - 5 days
- Thrombotic Risk Assessment
LabcorpTest code 117155CPT 85300, 85303, 85306, 85307, 85613, 85670, 85732, 86146, 86147, 86148Sodium citrate plasma, frozen, and serum, refrigeratedTAT 3 - 7 days
- Thrombotic Risk Reflex Panel
ARUP LaboratoriesTest code 3017156CPT 81240, 81241, 85300, 85303, 85306, 85307, 85520, 85525, 85598, 85610, 85613, 85670, 85730Light blue (sodium citrate) AND lavender (EDTA) AND serum separator tube (SST).TAT 2-7 days
- Thrombotic Risk, Congenital
LabcorpTest code 117140CPT 85300, 85303, 85306, 85307Sodium citrate plasma, frozenTAT 3 - 7 days
- Thrombotic Risk, Congenital (Extended)
LabcorpTest code 117185CPT 83090, 85240, 85300, 85303, 85306, 85307, 85415Sodium citrate plasma, frozen, and for homocysteine, plasma (preferred); serum iTAT 3 - 7 days
Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations
Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code.
Submit your lab's test menu → Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.