Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Labcorp 300 PLUS Carrier Panel (No X-Linked)

Labcorp 300 PLUS Carrier Panel (No X-Linked) (Women's Health): Labcorp test 898157

Labcorp test 898157, CPT 81443. Specimen: Whole blood or Oragene Dx 500 saliva kit or ORAcollect Dx OCD-100 buccal swabs or genomic DNA (gDNA) extracted from non-. Turnaround: 10 - 21 days.

Labcorp 300 PLUS Carrier Panel (No X-Linked) is Labcorp test code 898157, billed with CPT 81443. Specimen: Whole blood or Oragene Dx 500 saliva kit or ORAcollect Dx OCD-100 buccal swabs or genomic DNA (gDNA) extracted from non-fetal, non-tumor sou. Turnaround time: 10 - 21 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Michigan Medicine Laboratories (MLabs).
LaboratoryLabcorp
CLIA number34D0655059
Test code898157 (Women's Health)
CPT81443
LOINC55752-0
SpecimenWhole blood or Oragene Dx 500 saliva kit or ORAcollect Dx OCD-100 buccal swabs or genomic DNA (gDNA) extracted from non-fetal, non-tumor sources only Whole blood or Oragene Dx 500 saliva kit Whole blood or Oragene Dx 500 saliva kit or ORAcollect Dx OCD-100 buccal swabs or genomic DNA (gDNA) extracted from non-fetal, non-tumor sources only
Volume4 mL whole blood or Oragene Dx 500 saliva kit or 2 ORAcollect Dx OCD-100 buccal swabs or 5 micrograms (μg) of gDNA with a concentration of 50 ng/μL 4 mL whole blood or Oragene Dx saliva kit 4 mL whole blood or Oragene Dx 500 saliva kit or 2 ORAcollect Dx OCD-100 buccal swabs or 5 micrograms (μg) of gDNA with a concentration of 50 ng/μL
Minimum volume3 mL whole blood or Oragene Dx 500 saliva kit or 2 ORAcollect Dx OCD-100 buccal swabs or 5 μg of extracted DNA at a minimum concentration of 50 ng/μL 3 mL whole blood or Oragene Dx saliva kit 3 mL whole blood or Oragene Dx 500 saliva kit or 2 ORAcollect Dx OCD-100 buccal swabs or 5 μg of extracted DNA at a minimum concentration of 50 ng/μL
ContainerLavender-top (EDTA) tube or Oragene Dx 500 saliva collection kit or ORAcollect Dx OCD-100 buccal swabs or 2 mL microcentrifuge tube with screw cap Lavender-top (EDTA) tube or Oragene Dx 500 Saliva Collection Kit Lavender-top (EDTA) tube or Oragene Dx 500 saliva collection kit or ORAcollect Dx OCD-100 buccal swabs or 2 mL microcentrifuge tube with screw cap
Turnaround time10 - 21 days In some cases, additional time may be required for confirmatory or reflex tests.
Storage / transportFor blood, saliva and buccal, maintain specimen at room temperature or refrigerate at 4°C. Do not freeze. For gDNA, room temperature is preferred, or refrigerate at 4°C. Frozen also is accepted if shipped on ice packs. Maintain specimen at room temperature or refrigerate at 4°C. Do not freeze . For blood, saliva and buccal, maintain specimen at room temperature or refrigerate at 4°C. Do not freeze. For gDNA, room temperature is preferred, or refrigerate at 4°C. Frozen also is accepted if shipped on ice packs .

Also known as: Carrier screening; Pan-ethnic carrier screening; Expanded carrier testing

Test includes

This test includes the following genes: ABCA3, ABCC8, ABCD4, ACADM, ACADVL, ACAT1, ADA, ADAMTS2, ADGRV1, AGA, AGL, AGPS, AGXT, AHI1, AIRE, AK2, ALDH3A2, ALDOB, ALG1, ALG6, ALMS1, ALPL, AMT, ANO10, ARL13B, ARL6, ARSA, ARSB, ASL, ASPA, ASS1, ATM, ATP7B, B9D1, B9D2, BBS1, BBS10, BBS12, BBS2, BBS4, BBS5, BBS7, BBS9, BCKDHA, BCKDHB, BCS1L, BLM, BRIP1, BTD, CAPN3, CBS, CC2D2A, CCDC88C, CD247, CD3D, CD3E, CD3G, CD8A, CDH23, CEP104, CEP290, CERKL, CFTR, CHRNE, CIB2, CLCN1, CLN3, CLN5, CLN6, CLN8, CLRN1, CNGA1, CNGB1, CNGB3, COL4A3, COL4A4, COL7A1, CORO1A, CPLANE1, CPS1, CPT2, CTNS, CTSA, CTSD, CTSF, CWC27, CYP11A1, CYP11B1, CYP17A1, CYP21A2, CYP27A1, CYP27B1, DBT, DCLRE1C, DDB2, DHCR7, DHDDS, DLD, DOCK8, DYNC2H1, DYSF, ELP1, ERCC2, ERCC3, ERCC4, ERCC5, ETHE1, EVC2, EYS, FAH, FAM161A, FANCA, FANCC, FANCD2, FANCE, FANCF, FANCG, FANCI, FANCL, FBXL4, FKRP, FKTN, FMO3, FOXN1, FOXRED1, FRAS1, FREM2, FUCA1, G6PC1 (G6PC), GAA, GALC, GALE, GALK1, GALNS, GALT, GAMT, GATM, GBA1 (GBA), GBE1, GCDH, GJB2, GLB1, GLDC, GNPAT, GNPTAB, GNS, GRHPR, GRIP1, GSS, GUSB, HADHA, HBA1, HBA2, HBB, HEXA, HEXB, HGSNAT, HLCS, HMGCL, HOGA1, HPS1, HPS3, HSD17B4, HSD3B2, HYLS1, IDUA, IFT140, IKBKB, IL2RA, IL7R, INPP5E, IVD, JAK3, KCTD7, KIF14, LAMA3, LAMB3, LAMC2, LCK, LIG4, LIPA, LMBRD1, LOXHD1, LRP2, LRPPRC, MAK, MALT1, MAN2B1, MANBA, MCCC1, MCCC2, MCEE, MCOLN1, MCPH1, MEFV, MFSD8, MKKS, MKS1, MLC1, MMAA, MMAB, MMACHC, MMADHC, MMUT (MUT), MPI, MPL, MTHFD1, MTTP, MVK, NAGA, NAGLU, NBN, NDUFAF2, NDUFAF5, NDUFS4, NDUFS6, NDUFS7, NDUFV1, NEB, NEU1, NHEJ1, NPC1, NPC2, NPHP1, NPHP3, NPHS1, NPHS2, OCA2, OTOF, PAH, PCCA, PCCB, PCDH15, PDHB, PDHX, PDP1, PEX1, PEX10, PEX11B, PEX12, PEX13, PEX14, PEX16, PEX19, PEX2, PEX26, PEX3, PEX5, PEX6, PEX7, PGM3, PHGDH, PKHD1 PMM2, PNP, POLG, POLH, POMGNT1, POMT1, POMT2, POR, PPT1, PRCD, PRF1, PRKDC, PSAP, PTPRC, RAG1, RAG2, RARS2, RLBP1, RMRP, RNASEH2B, RPGRIP1L, SACS, SCO2, SDCCAG8, SGCA, SGCB, SGCD, SGCG, SGSH, SLC12A6, SLC17A5, SLC19A3, SLC22A5, SLC25A13, SLC25A20, SLC26A2, SLC26A4, SLC35A3, SLC37A4, SMN1, SMPD1, STAR, STK4, STX11, STXBP2, SUMF1, SURF1, SYNE4, TCTN1, TCTN2, TCTN3, TF, TMEM138, TMEM216, TMEM231, TMEM237, TMEM67, TNXB, TPP1, TRAPPC11, TRIM32, TTC7A, TTC8, TTPA, TYR, UNC13D, USH1C, USH1G, USH2A, VPS13B, WHRN, XPA, XPC and ZAP70 .

Use

This test is used for pan-ethnic carrier screening and includes more than 300 clinically relevant genetic disorders. No X-linked disorders are included in this panel.

Methodology

Next-generation sequencing : identifies genetic variants, including single nucleotide variants (SNVs), insertions, deletions and copy number variants (CNVs). Confirmation of the presence and location of reportable variants is performed as needed based on stringent criteria using one of several validated orthogonal approaches.

Collection instructions

Standard phlebotomy; follow Oragene Dx 500 saliva kit collection instructions. Follow ORAcollect Dx OCD-100 buccal swab collection instructions. Do not eat, drink, smoke or chew gum 30 minutes prior to saliva or buccal collection. For gDNA, DNA must be extracted in a CLIA-certified laboratory and eluted in an EDTA-free buffer. Standard phlebotomy; follow Oragene Dx 500 Saliva Collection Kit instructions. Do not eat, drink, smoke or chew gum 30 minutes prior to collection . Standard phlebotomy; follow Oragene Dx 500 saliva kit collection instructions. Follow ORAcollect Dx OCD-100 buccal swab collection instructions. Do not eat, drink, smoke or chew gum 30 minutes prior to saliva or buccal collection. For gDNA, DNA must be extracted in a CLIA-certified laboratory and eluted in an EDTA-free buffer .

Stability

Whole blood: 90 days at room temperature or 4°C Saliva: 60 days at room temperature Buccal: 60 days at room temperature gDNA: room temperature (preferred) or refrigerate 3 years at 4°C Whole blood: 90 days at room temperature or 4°C Saliva: 60 days at room temperature Whole blood: 90 days at room temperature or 4°C Saliva: 60 days at room temperature Buccal: 60 days at room temperature gDNA: room temperature (preferred) or refrigerate 3 years at 4°C

Causes for rejection

Hemolyzed specimen; quantity not sufficient for analysis; improper container; improper storage temperature; specimen from an individual who has undergone allogeneic bone marrow transplant Frozen or hemolyzed specimen; quantity not sufficient for analysis or in improper container ; specimen from an individual who has undergone allogeneic bone marrow transplant Hemolyzed specimen; quantity not sufficient for analysis; improper container; improper storage temperature ; specimen from an individual who has undergone allogeneic bone marrow transplant

Special instructions

Test orders must include an attestation that the provider has the patient's informed consent for genetic testing. The genes BCHE, F2,F5, F11, GP1BA, GP9, HFE, HGD, TFR2 and SERPINA1 are available as an add-on panel that can be ordered at the same time as the primary panel. Genes in the add-on panel do not meet the criteria for primary carrier screening and should be considered in the context of individual patient testing.

Limitations

Technologies used do not detect germline mosaicism and do not rule out the presence of large chromosomal aberrations including rearrangements and gene fusions, or variants in regions or genes not included in this test, or possible inter/intragenic interactions between variants or repeat expansions. Variant classification and/or interpretation may change over time if more information becomes available. Updated classifications are available upon request. False positive or false negative results may occur for reasons that include: rare genetic variants, sex chromosome abnormalities, pseudogene interference, blood transfusions, bone marrow transplantation, somatic or tissue-specific mosaicism,…

LOINC map

Result codeResult nameUnitsResult LOINC
300 PLUS Carrier Panel (No XL)898273Additional Information55752-0

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 81443

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation