Labcorp High Frequency Panel (No X-Linked) (Women's Health): Labcorp test 898155
Labcorp test 898155, CPT 81443. Specimen: Whole blood or Oragene Dx 500 saliva kit or ORAcollect Dx OCD-100 buccal swabs or genomic DNA (gDNA) extracted from non-. Turnaround: 10 - 21 days.
Also known as: Carrier screening; Pan-ethnic carrier screening; Expanded carrier testing
Test includes
This test includes the following genes: ABCA3, ABCC8, ACADM, ACADVL, ACAT1, AGA, AGXT, AHI1, AIRE, ALDOB, ALPL, ANO10, ARSA, ASL, ASPA, ATP7B, BBS1, BBS2, BCKDHB, BLM, BTD, CBS, CC2D2A, CCDC88C, CEP290, CFTR, CHRNE, CLCN1, CLRN1, CNGB3, COL7A1, CPT2, CYP11A1, CYP21A2, CYP27A1, CYP27B1, DHCR7, DHDDS, DLD, DYNC2H1, ELP1, ERCC2, EVC2, FAH, FANCC, FKRP, FKTN, FMO3, G6PC1 (G6PC), GAA, GALT, GBA1 (GBA), GBE1, GJB2, GNPTAB, GRIP1, HBA1, HBA2, HBB, HEXA, HPS1, HPS3, IDUA, LRP2, MCCC2, MCOLN1, MCPH1, MLC1, MMACHC, MMUT (MUT), MVK, NAGA, NEB, NPHS1, OCA2, PAH, PCDH15, PKHD1, PMM2, POLG, PRF1, RARS2, RNASEH2B, SCO2, SLC19A3, SLC26A2, SLC26A4, SLC37A4, SMN1, SMPD1, TF, TMEM216, TNXB, TYR, USH2A and XPC .
Use
This test is used for pan-ethnic carrier screening and includes some of the genes included in the American College of Medical Genetics (ACMG) Tier 3 category. No X-linked disorders are included in this panel.
Methodology
Next-generation sequencing: identifies genetic variants, including single nucleotide variants (SNVs), insertions, deletions and copy number variants (CNVs). Confirmation of the presence and location of reportable variants is performed as needed based on stringent criteria using one of several validated orthogonal approaches.
Collection instructions
Standard phlebotomy; follow Oragene Dx 500 saliva kit collection instructions. Follow ORAcollect Dx OCD-100 buccal swab collection instructions. Do not eat, drink, smoke or chew gum 30 minutes prior to saliva or buccal collection. For gDNA, DNA must be extracted in a CLIA-certified laboratory and eluted in an EDTA-free buffer. Standard phlebotomy; follow Oragene Dx 500 Saliva Collection Kit instructions. Do not eat, drink, smoke or chew gum 30 minutes prior to collection . Standard phlebotomy; follow Oragene Dx 500 saliva kit collection instructions. Follow ORAcollect Dx OCD-100 buccal swab collection instructions. Do not eat, drink, smoke or chew gum 30 minutes prior to saliva or buccal collection. For gDNA, DNA must be extracted in a CLIA-certified laboratory and eluted in an EDTA-free buffer .
Stability
Whole blood: 90 days at room temperature or 4°C Saliva: 60 days at room temperature Buccal: 60 days at room temperature gDNA: room temperature (preferred) or refrigerate 3 years at 4°C Whole blood: 90 days at room temperature or 4°C Saliva: 60 days at room temperature Whole blood: 90 days at room temperature or 4°C Saliva: 60 days at room temperature Buccal: 60 days at room temperature gDNA: room temperature (preferred) or refrigerate 3 years at 4°C
Causes for rejection
Hemolyzed specimen; quantity not sufficient for analysis; improper container; improper storage temperature; specimen from an individual who has undergone allogeneic bone marrow transplant Frozen or hemolyzed specimen; quantity not sufficient for analysis or in improper container ; specimen from an individual who has undergone allogeneic bone marrow transplant Hemolyzed specimen; quantity not sufficient for analysis; improper container; improper storage temperature ; specimen from an individual who has undergone allogeneic bone marrow transplant
Special instructions
Test orders must include an attestation that the provider has the patient's informed consent for genetic testing. The genes BCHE, F2,F5, F11, GP1BA, GP9, HFE, HGD, TFR2 and SERPINA1 are available as an add-on panel that can be ordered at the same time as the primary panel. Genes in the add-on panel do not meet the criteria for primary carrier screening and should be considered in the context of individual patient testing.
Limitations
Technologies used do not detect germline mosaicism and do not rule out the presence of large chromosomal aberrations including rearrangements and gene fusions, or variants in regions or genes not included in this test, or possible inter/intragenic interactions between variants or repeat expansions. Variant classification and/or interpretation may change over time if more information becomes available. Updated classifications are available upon request. False positive or false negative results may occur for reasons that include: rare genetic variants, sex chromosome abnormalities, pseudogene interference, blood transfusions, bone marrow transplantation, somatic or tissue-specific mosaicism,…
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| High Frequency Panel (No XL) | 898273 | Additional Information | 55752-0 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 81443
- Comprehensive Immune and Cytopenias Panel
- Labcorp 100 PLUS Carrier Panel
- Labcorp 100 PLUS Carrier Panel (No X-Linked)
- Labcorp 300 PLUS Carrier Panel
- Labcorp 300 PLUS Carrier Panel (No X-Linked)
- Labcorp 500 PLUS Carrier Panel
- Labcorp 500 PLUS Carrier Panel (No X-Linked)
- Labcorp 700 PLUS Carrier Panel (No X-Linked)
- Labcorp 790 PLUS Carrier Panel
- Labcorp High Frequency Carrier Panel
- Labcorp High Frequency Panel (No X-Linked)
- Labcorp 100 PLUS Carrier Panel
- Labcorp 100 PLUS Carrier Panel (No X-Linked)
- Labcorp 300 PLUS Carrier Panel
- Labcorp 300 PLUS Carrier Panel (No X-Linked)
- Labcorp 500 PLUS Carrier Panel
- Labcorp 500 PLUS Carrier Panel (No X-Linked)
- Labcorp 700 PLUS Carrier Panel (No X-Linked)
- Labcorp 790 PLUS Carrier Panel
- Labcorp High Frequency Carrier Panel
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation