Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Labcorp 100 PLUS Carrier Panel

Labcorp 100 PLUS Carrier Panel: Labcorp test 898101

Labcorp test 898101, CPT 81443. Specimen: Whole blood or Oragene Dx 500 saliva kit. Turnaround: 10 - 21 days.

Labcorp 100 PLUS Carrier Panel is Labcorp test code 898101, billed with CPT 81443. Specimen: Whole blood or Oragene Dx 500 saliva kit. Turnaround time: 10 - 21 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Michigan Medicine Laboratories (MLabs).
LaboratoryLabcorp
CLIA number34D0655059
Test code898101
CPT81443
LOINC107556-3, 55752-0, 62364-5, 77202-0, 8251-1
SpecimenWhole blood or Oragene Dx 500 saliva kit
Volume4 mL whole blood or Oragene Dx saliva kit
Minimum volume3 mL whole blood or Oragene Dx saliva kit
ContainerLavender-top (EDTA) tube or Oragene Dx 500 Saliva Collection Kit
Turnaround time10 - 21 days In some cases, additional time may be required for confirmatory or reflex tests.
Storage / transportMaintain specimen at room temperature or refrigerate at 4°C. Do not freeze.

Also known as: Carrier screening; Pan-ethnic carrier screening; Expanded carrier testing

Test includes

This test includes the following genes: ABCC8, ACADM, ACADVL, ACAT1, ADA, ADAMTS2, AGA, AGL, AGXT, ALDH3A2, ALDOB, ALPL, AMT, ARSA, ARSB, ASL, ASPA, ASS1, ATM, ATP7B, BBS1, BBS10, BBS2, BCKDHA, BCKDHB, BCS1L, BLM, CBS, CFTR, CLN3, CLN5, CLN8, CLRN1, COL4A3, CPS1, CPT2, CTNS, CTSA, DHCR7, DHDDS, DLD, DMD, ELP1, ERCC5, ETHE1, FAH, FANCC, FKTN, FMR1, FOXRED1, FUCA1, G6PC1 (G6PC), GAA, GALC, GALNS, GALT, GAMT, GBA1 (GBA), GCDH, GLB1, GLDC, GNPTAB, GNS, GRHPR, GSS, GUSB, HADHA, HBA1, HBA2, HBB, HEXA, HEXB, HGSNAT, HLCS, HMGCL, HSD17B4, IDS, IDUA, IL2RG, LAMA3, LAMB3, LAMC2, LRPPRC, MAN2B1, MANBA, MCOLN1, MEFV, MMAA, MMAB, MMACHC, MMUT (MUT), MPL, MTTP, NAGLU, NBN, NDUFAF2, NDUFS4, NDUFS7, NDUFV1, NEB, NEU1, NPC1, NPC2, NPHS1, NPHS2, OTC, PAH, PCCA, PCCB, PCDH15, PDHA1, PEX1, PEX10, PEX12, PEX2, PEX26, PEX6, PEX7, PHGDH, PKHD1, PMM2, PPT1, RMRP, SACS, SGSH, SLC12A6, SLC17A5, SLC22A5, SLC25A20, SLC26A2, SLC35A3, SLC37A4, SMN1, SMPD1, SUMF1, SURF1, TMEM216, TPP1, TTPA, VPS13B, XPA and XPC .

Use

This test is used for pan-ethnic carrier screening and includes analysis of more than 100 clinically relevant genetic disorders.

Methodology

Next-generation sequencing: identifies genetic variants, including single nucleotide variants (SNVs), insertions, deletions and copy number variants (CNVs). Fragile X syndrome: cytosine-guanine-guanine (CGG) triplet repeats in the 5' untranslated region (5' UTR) of the FMR1 gene are detected by triplet repeat-primed PCR (RP-PCR) with fluorescently labeled primers followed by capillary electrophoresis. Confirmation of the presence and location of reportable variants is performed as needed based on stringent criteria using one of several validated orthogonal approaches.

Collection instructions

Standard phlebotomy; follow Oragene Dx 500 Saliva Collection Kit instructions. Do not eat, drink, smoke or chew gum 30 minutes prior to collection.

Stability

Whole blood: 90 days at room temperature or 4°C Saliva: 60 days at room temperature

Causes for rejection

Frozen or hemolyzed specimen; quantity not sufficient for analysis or in improper container; specimen from an individual who has undergone allogeneic bone marrow transplant

Special instructions

Test orders must include an attestation that the provider has the patient's informed consent for genetic testing.

Limitations

Technologies used do not detect germline mosaicism and do not rule out the presence of large chromosomal aberrations including rearrangements and gene fusions, or variants in regions or genes not included in this test, or possible inter/intragenic interactions between variants or repeat expansions. Variant classification and/or interpretation may change over time if more information becomes available. Updated classifications are available upon request. False positive or false negative results may occur for reasons that include: rare genetic variants, sex chromosome abnormalities, pseudogene interference, blood transfusions, bone marrow transplantation, somatic or tissue-specific mosaicism,…

LOINC map

Result codeResult nameUnitsResult LOINC
100 PLUS Carrier Panel898273Additional Information55752-0
100 PLUS Carrier Panel898086Partner Testing Recommended77202-0
100 PLUS Carrier Panel898279Next Steps107556-3
100 PLUS Carrier Panel898280Residual Risk8251-1
100 PLUS Carrier Panel898095Disclaimer62364-5
100 PLUS Carrier Panel898281Limitations Continued8251-1

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 81443

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation