Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Anti-Ro Profile, Ro52 and Ro60 (Anti-SS-A 52 kD and Anti-SS-A 60 kD Separately)

Anti-Ro Profile, Ro52 and Ro60 (Anti-SS-A 52 kD and Anti-SS-A 60 kD Separately): Labcorp test 505835

Labcorp test 505835, CPT 86235. Specimen: Serum.

Anti-Ro Profile, Ro52 and Ro60 (Anti-SS-A 52 kD and Anti-SS-A 60 kD Separately) is Labcorp test code 505835, billed with CPT 86235. Specimen: Serum. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC).
LaboratoryLabcorp
CLIA number34D0655059
Test code505835
CPT86235(x2)
LOINC—
SpecimenSerum
Volume1 mL
Minimum volume0.5 mL
ContainerSerum from red-top tube or serum from a gel tube
Storage / transportRefrigerated or frozen

Also known as: Antibodies to Ro52; 52 kilodalton and Ro60; 60 kilodalton Anti-SS-A

Use

This profile differentiates anti-Ro antibodies into anti-Ro52 and anti-Ro60, which are reported individually. Anti-Ro occur in 60% to 90% of patients with Sjögren’s Syndrome (SS), in 30% to 50% of patients with systemic lupus erythematosus (SLE) and less frequently in other autoimmune diseases. Historically, autoantibodies to both parts of the Ro (SS-A) antigen, Ro52 kilodaltons and Ro60 kilodaltons, have been used to comprise total anti-Ro. Now it is known that Ro52 and Ro60 proteins are not linked in the same particle. In addition, anti-Ro52 and anti-Ro60 antibodies are distinct from each other and have different clinical associations. The combination of both anti-Ro52 and anti-Ro60…

Methodology

Chemiluminescence Immunoassay

Collection instructions

Serum must be separated from cells within 45 minutes of venipuncture. Send serum in a plastic transport tube. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test required.

Stability

Room temperature: 48 hours Refrigerated: 14 days Frozen: 14 days Freeze/thaw cycles: Stable x3

Causes for rejection

Gross hemolysis, lipemia and icterus

Limitations

These measurements of anti-Ro52 and anti-Ro60 antibodies are performed by chemiluminescent immunoassays and their numeric results additively do not equal measurement of anti-Ro Total by enzyme immunoassay. Results should be interpreted in the context of other laboratory and clinical findings. Negative results do not exclude the possibility of autoimmune disease.

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 86235

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation