Anti-Centromere Ab by EIA (Enzyme Immunoassay): Labcorp test 169500

Labcorp test 169500, CPT 86235. Specimen: Serum. Turnaround: 10 days.

Anti-Centromere Ab by EIA (Enzyme Immunoassay) is Labcorp test code 169500, billed with CPT 86235. Specimen: Serum. Turnaround time: 10 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC).
LaboratoryLabcorp
CLIA number34D0655059
Test code169500
CPT86235
LOINC8068-9
SpecimenSerum
Volume2.0 mL
Minimum volume1.0 mL
ContainerGel-barrier tube, red-top tube
Turnaround time10 days
Storage / transportRefrigerated or frozen

Also known as: anti-CENP-A; anti-CENP-B; anticentromere antibodies

Use

The presence of anti-centromere antibodies (ACA) is predictive of the development of Systemic Sclerosis (SSc) in either apparently health individuals or in patients with Connective Tissue Disease (CTD). ACA is found in approximately 30% of patients with SSc and has a distribution range of 11% to 40% worldwide with greater frequency in Caucasians than Asians or African-Americans. ACA is recognized as one of the serological markers of limited SSc with features of long lasting Raynaud's disease and subsequent development of progressive thickening of skin at the extremities, neck and face. About 10% to 20% of ACA-positive patients develop pulmonary arterial hypertension. ACA has been found to…

Methodology

Enzyme Immunoassay

Collection instructions

Draw blood in gel-barrier tube and centrifuge. If red-top tube is used, centrifuge within 45 minutes of draw, remove the serum, place in a plastic transport tube and tightly stopper the tube.

Stability

TemperaturePeriod
Room temperature8 hours
Refrigerated14 days
Frozen5 years
Freeze/thaw cyclesStable x6

LOINC map

Result codeResult nameUnitsResult LOINC
169501Anti-Centromere Ab by EIAUnits8068-9

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 86235

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation