Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Antinuclear Ab Profile, 11-biomarker Profile, by Multiplex Immunoassay, dsDNA, RNP, Sm, SS-A, SS-B, Scl-70, Chromatin, Jo-1, Centromere B, Sm/RNP, Ribosomal P

Antinuclear Ab Profile, 11-biomarker Profile, by Multiplex Immunoassay, dsDNA, RNP, Sm, SS-A, SS-B, Scl-70, Chromatin, Jo-1, Centromere B, Sm/RNP, Ribosomal P: Labcorp test 164920

Labcorp test 164920, CPT 83516, 86225, 86235. Specimen: Serum. Turnaround: 2 - 3 days.

Antinuclear Ab Profile, 11-biomarker Profile, by Multiplex Immunoassay, dsDNA, RNP, Sm, SS-A, SS-B, Scl-70, Chromatin, Jo-1, Centromere B, Sm/RNP, Ribosomal P is Labcorp test code 164920, billed with CPT 83516, 86225, 86235. Specimen: Serum. Turnaround time: 2 - 3 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code164920
CPT83516; 86225; 86235(x9)
LOINC11090-8, 27048-8, 27416-7, 29374-6, 5130-0
SpecimenSerum
Volume1 mL
Minimum volume0.5 mL ( Note: This volume does not allow for repeat testing.)
ContainerRed-top tube or gel-barrier tube
Turnaround time2 - 3 days
Storage / transportRoom temperature

Also known as: ANA Comprehensive Plus Profile

Test includes

Centromere B; chromatin; dsDNA; Jo-1; ribosomal P; RNP; scl-70; Sjögren's A; Sjögren's B; Sm/RNP; Smith (Sm)

Use

Detect antibodies associated with SLE and mixed connective tissue disease. Sm antibodies are highly specific for SLE. RNP antibodies are found with a variety of rheumatoid diseases. RNP, Sm, SS-A, SS-B, Scl-70, and Jo-1 are extractable nucleoprotein complexes found in the nucleus and/or cytoplasm of substrate cells. Autoantibodies to the ribosomal P protein represent a highly specific marker for the diagnosis of SLE, where they have been associated with certain clinical manifestations. The native protein SmRNP contains two different regions: Sm and RNP that are different regions of the same macromolecule. SmRNP is the best antigen for detection of antibodies to either Sm or RNP but cannot…

Methodology

Multiplex flow immunoassay

Stability

TemperaturePeriod
Room temperature14 days
Refrigerated14 days
Frozen14 days
Freeze/thaw cyclesStable x3

Causes for rejection

Hemolysis; lipemia; gross bacterial contamination; icterus

Special instructions

Test is intended to be used as a follow-up to Antinuclear Antibodies (ANA) Direct [164855] .

LOINC map

Result codeResult nameUnitsResult LOINC
Anti-DNA (DS) Ab QnIU/mL5130-0
RNP AntibodiesAI29374-6
Smith AntibodiesAI11090-8
Smith/RNP AntibodiesAI27048-8
Antiscleroderma-70 AntibodiesAI27416-7

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 83516, 86225, 86235

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation