Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Natural Killer Cell and Activated T-Cell Profile/IL-2r

Natural Killer Cell and Activated T-Cell Profile/IL-2r: Labcorp test 502500

Labcorp test 502500, CPT 86356, 86357, 86359. Specimen: Whole blood. Turnaround: 1 - 3 days.

Natural Killer Cell and Activated T-Cell Profile/IL-2r is Labcorp test code 502500, billed with CPT 86356, 86357, 86359. Specimen: Whole blood. Turnaround time: 1 - 3 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code502500
CPT86356; 86357; 86359
LOINC26997-7, 42188-3, 42189-1, 8122-4, 8124-0
SpecimenWhole blood
VolumeFill tube(s) to capacity.
ContainerLavender-top (EDTA) tube and yellow-top (ACD-A) or (ACD-B) tube
Turnaround time1 - 3 days
Storage / transportMaintain specimen at room temperature.

Also known as: CD25; Interleukin-2 Receptor; TAC Antigen

Test includes

This test includes: percentage CD3; absolute CD3; percentage CD3CD25 (IL-2 receptor); absolute CD3CD25; percentage CD3CD56 (NK); total CD3CD56 (NK); CBC with differential; total lymphocyte count.

Use

This test is used to assess changes in T-lymphocyte surface markers that may indicate immune stimulation.

Methodology

Flow cytometry

Collection instructions

Immediately invert the tube eight to 10 times after collection. To maintain cellular viability, collect the specimen in either a yellow-top tube (ACD-A or ACD-B) for arrival at the laboratory within 48 hours of collection, or a lavender-top (EDTA) tube for arrival at the laboratory within 24 hours of collection. Record the date and time of venipuncture on both the tube(s) and the test requisition form.

Stability

TemperaturePeriod
Room temperatureYellow-top (ACD-A) or (ACD-B) tube: 2 days
Lavender-top (EDTA) tube: 1 dayRefrigerated
UnstableFrozen
UnstableFreeze/thaw cycles

Causes for rejection

Hemolysis; specimen refrigerated or frozen; clotted specimen; contaminated specimen

Reference range

Reference intervals for adults have been established by the laboratory. See table. Adult Reference Intervals for Lymphocyte Immunophenotyping CD 95% Confidence Interval Percentage Cells/mm Minimum Maximum Minimum Maximum CD3 CD3CD25 CD3CD56

Limitations

This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.

LOINC map

Result codeResult nameUnitsResult LOINC
Ab NK (CD56/16)/uL42188-3
% NK (CD56/16)%42189-1
Absolute CD 3/uL8122-4
% CD 3 Pos. Lymph.%8124-0
Abs.CD3+CD25+ Lymphs/uL26997-7

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 86356, 86357, 86359

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation