Natural Killer Cells Enumeration: ARUP Laboratories test 0092404
ARUP Laboratories test 0092404, CPT 86357. Specimen: Lavender (EDTA), pink (K2EDTA), or green (sodium or lithium heparin). Hemogard tubes are preferred for laboratory automa. Turnaround: 1-3 days.
Also known as: Natural Killer Cell CD56/CD16, Percent and Absolute; NK absolute cell count and percentage
Use
Evaluate NK cells in patients with suspected immune deficiency.
Methodology
Quantitative Flow Cytometry
Collection instructions
Transport 4 mL whole blood. (Min: 0.5 mL)
Stability
EDTA: Ambient: 72 hours; Refrigerated: Unacceptable; Frozen: Unacceptable Heparin: Ambient: 48 hours; Refrigerated: Unacceptable; Frozen: Unacceptable New York State Clients: Same as the above.
Causes for rejection
Clotted or hemolyzed specimens.
Reference range
Test Number Components Reference Interval % Natural Killer Cells Age Reference Interval (Percent) 0-6 days 8-62 1 week-1 month 3-23 2-4 months 2-20 5-8 months 2-36 9-14 months 1-64 15-23 months 1-96 2-4 years 2-25 5-9 years 2-31 10-15 years 4-51 16-64 years 4-26 65 years or older 5-28 Absolute Natural Killer Cells Age Reference Interval (cells/µL) 0-6 days 500-3100 1 week-1 month 140-1900 2-4 months 97-2000 5-8 months 68-3900 9-14 months 71-3500 15-23 months 55-4000 2-4 years 61-510 5-9 years 70-590 10-15 years 92-1200 16-64 years 78-470 65 years or older 74-620
Remarks
Specimens must be analyzed within stability times provided. Some medication may affect immunophenotyping results and should be provided on the patient test request form.
Performed
Sun-Sat
Compliance Category
Laboratory Developed Test (LDT)
New York DOH Approval Status
This test is New York state approved.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 0092403 | Natural Killer Cell Information | 77202-0 | |
| 0095701 | % Natural Killer Cells | 32519-1 | |
| 0095702 | Absolute Natural Killer Cells | 20604-5 |
View this test on ARUP Laboratories's website → · Last checked 2026-11-29
Other tests billed with CPT 86357
- Helper/Suppressor and Natural Killer Cell Profile
- Immunodeficiency (CDC) Panel
- Lymphocyte Activity Profile
- Lymphocyte Subset Panel 5 - Total Lymphocyte Enumeration
- Lymphocyte Subset Panel 6 - Total Lymphocyte Enumeration with CD45RA and CD45RO
- Lymphocyte Subset Panel 7 - Congenital Immunodeficiencies
- Natural Killer Cell and Activated T-Cell Profile/IL-2r
- Natural Killer Cell and Natural Killer T-Cell Panel
- Natural Killer Cell Surface Antigen (CD3-CD56+ Marker Analysis)
- T- and B-Lymphocyte and Natural Killer Cell Profile
- T-Lymph Markers and NK
Search the National Lab Test Directory · All ARUP Laboratories tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation