Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › ARUP Laboratories › Leukocyte Adhesion Deficiency Panel

Leukocyte Adhesion Deficiency Panel: ARUP Laboratories test 2004359

ARUP Laboratories test 2004359, CPT 86356. Specimen: Green (Na heparin) or purple (KEDTA).. Turnaround: 1-3 days.

Leukocyte Adhesion Deficiency Panel is ARUP Laboratories test code 2004359, billed with CPT 86356. Specimen: Green (Na heparin) or purple (KEDTA).. Turnaround time: 1-3 days. Performing laboratory: ARUP Laboratories, CLIA 46D0523979 (Salt Lake City, UT). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, Labcorp.
LaboratoryARUP Laboratories
CLIA number46D0523979
Test code2004359
CPT86356 x4
LOINC17109-0, 17110-8, 17117-3, 17121-5
SpecimenGreen (Na heparin) or purple (KEDTA).
Turnaround time1-3 days
Storage / transportRoom temperature or refrigerated.

Also known as: Beta 2 integrins; CD11a, CD11b; CD15s; CD18; LAD I, II determination

Use

Aids in the diagnosis of type I and II leukocyte adhesion deficiency. Panel measures CD11a, CD11b, CD15s, and CD18 on neutrophils.

Methodology

Semi-Quantitative Flow Cytometry

Collection instructions

Transport 5 mL whole blood. (Min: 1 mL) Specimen must be analyzed within 72 hours of collection.

Stability

Ambient: 72 hours; Refrigerated: 72 hours; Frozen: Unacceptable.

Causes for rejection

Clotted or hemolyzed specimens. Frozen specimens.

Reference range

Test Number Components Reference Interval % CD18 99-100 % CD11b 96-100 % CD15s 95-100 % CD11a 97-100

Performed

Sun-Sat

Compliance Category

Laboratory Developed Test (LDT)

New York DOH Approval Status

This test is not New York state approved. Due to short specimen stability it is recommended that this testing be submitted directly to a New York state-approved laboratory. Do not submit sample to ARUP.

LOINC map

Result codeResult nameUnitsResult LOINC
0095818% CD1817121-5
0095922% CD11b17110-8
0095957% CD15s17117-3
3004266% CD11a17109-0

View this test on ARUP Laboratories's website → · Last checked 2026-11-29

Other tests billed with CPT 86356

Search the National Lab Test Directory · All ARUP Laboratories tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation