GlycoMark® and Hb A1c: Labcorp test 502226
Labcorp test 502226, CPT 83036, 84378. Specimen: Whole blood and serum or plasma. Turnaround: 3 - 10 days.
Also known as: Hb A 1c and 1-5 Anhydroglucitol
Use
GlycoMark® testing provides an estimate of the patient's postmeal glucose during a one- to two-week period, making it ideal for intermediate term monitoring of glycemic control in diabetic patients. GlycoMark® testing can also help to monitor the effectiveness of therapeutics targeting postprandial glucose (PPG), and is a useful adjunct to routine A 1c testing, because it responds more rapidly and sensitively to hyperglycemia than A 1c . Hb A 1c testing provides an estimate of the patient's average blood glucose over a period of two to three months. Hb A 1c testing helps assess the long term diabetic control for individuals with diabetes mellitus.
Methodology
Roche Tina Quant; enzymatic
Collection instructions
Serum or plasma must be separated from cells within 45 minutes of venipuncture. Send serum or plasma in a plastic transport tube.
Stability
Whole blood Temperature Period Room temperature 14 days Refrigerated 14 days Frozen 14 days Freeze/thaw cycles Stable x3 Serum or plasma Temperature Period Room temperature 7 days Refrigerated 14 days Frozen 14 days Freeze/thaw cycles Stable x6
Reference range
GlycoMark®: • <18 years: Not established • Adult male: 10.7−32.0 μg/mL • Adult female: 6.8−29.3 μg/mL • Glycemic control goal for diabetic patients: >10 Hb A 1c (percent): • Normal: <5.7% • Increased risk for diabetes: 5.7% to 6.4% • Ongoing hyperglycemia: >6.4%
Limitations
Individuals using INVOKANA® may demonstrate low levels of 1,5-AG. 1,5-AG blood levels are falsely lowered by the diabetes drug INVOKANA®, which prevents reabsorption of 1,5-AG in the kidneys. INVOKANA® belongs to new class of diabetes medication known as sodium-glucose cotransporter 2 (SGLT2) inhibitors, which block reabsorption of glucose in the kidneys, and other SGLT2 inhibitors may have the same effect. INVOKANA® is a trademark of Janssen Pharmaceuticals, Inc. Persistently positive urinary glucose levels, or oxyhyperglycemia after gastrectomy, may result in a low 1,5-AG value. Low values have also been observed in pregnancy, terminal stage renal failure, dialysis patients, advanced…
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| Hb A1c Diabetic Assessment | %Hb | 4548-4 | |
| GlycoMark(R)(1,5 AG) | ug/mL | 53835-5 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 83036, 84378
- Cardiorenal-Glycemic Status
- Chronic Fatigue Profile
- Diabetes Risk–Asymptomatic Adults
- Hemoglobin (Hb) A1c
- Hemoglobin (Hb) A1c With eAG
- Hemoglobin (Hb) A1c With GlycoMark® Reflex
- Hemoglobin A1c
- Hemoglobin A1C
- Post-Bariatric Surgery Comprehensive Profile
- Pre-Bariatric Surgery Comprehensive Profile
- Weight Management Baseline Profile
- Weight Management Baseline Profile With Liver Evaluation
- Weight Management Baseline Profile With TSH
- Weight Management Follow-Up Profile
- Hemoglobin (Hb) A1c
- Hemoglobin (Hb) A1c With eAG
- 1,5 Anhydroglucitol
- 1,5 Anhydroglucitol Quantitative, Serum or Plasma
- Galactose-1-Phosphate
- Galactose-1-Phosphate in Red Blood Cells
- GlycoMark®
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation