Diabetes Risk–Asymptomatic Adults: Labcorp test 090400

Labcorp test 090400, CPT 82947, 83036. Specimen: Whole blood and plasma. Turnaround: Within 1 day.

Diabetes Risk–Asymptomatic Adults is Labcorp test code 090400, billed with CPT 82947, 83036. Specimen: Whole blood and plasma. Turnaround time: Within 1 day. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code090400
CPT82947; 83036
LOINC1558-6, 4548-4
SpecimenWhole blood and plasma
Volume4 mL whole blood and entire collection of plasma
Minimum volume4 mL whole blood and 0.5 mL plasma
ContainerHemoglobin A1c: lavender-top (EDTA) tube; green-top (lithium heparin) tube; or gray-top (sodium fluoride) tube Glucose, Plasma: gray-top (sodium fluoride) tube or green-top (lithium heparin) tube
Turnaround timeWithin 1 day
Storage / transportMaintain A1c and FPG specimens at room temperature.

Also known as: Diabetes Risk Assessment; Prediabetes Screen

Use

Screen for prediabetes and diabetes in asymptomatic adults

Methodology

A1c: Roche Tina-Quant Hemoglobin A1c which is NGSP certified and standardized to the DCCT reference assay. Plasma glucose: enzymatic

Collection instructions

Hemoglobin A1c: The usual precautions in the collection of venipuncture samples should be observed. The sample must be free of clots. Samples with any hematocrit disorders can lead to erroneous results. Send the entire tube to the laboratory. FPG: Label specimen as plasma. Mix well.

Stability

TemperaturePeriod
Room temperature14 days
Refrigerated14 days
Frozen14 days
Freeze/thaw cyclesStable x3

Patient preparation

A1c: None FPG: Blood should be drawn in the morning after an overnight fast (no caloric intake for at least eight hours), during which time the individual may consume water.

Causes for rejection

A1c: clotted specimen; gross hemolysis FPG: gross hemolysis; improper labeling

Reference range

Hemoglobin (Hb) A1c (%) Fasting Plasma Glucose mg/dL Diabetes >6.4 >125 Prediabetes 5.7–6.4 Glycemic Control for Adults with Diabetes <7.0 N/A Normal 4.8–5.6 For selected individual patients, providers might reasonably suggest even lower A1c goals than the general goal of <7%, if this can be achieved without significant hypoglycemia or other adverse effects of treatment. Such patients might include those with short duration of diabetes, long life expectancy, and no significant CVD. Conversely, less‐stringent A1c goals than the general goal of <7% may be appropriate for patients with a history of severe hypoglycemia, limited life expectancy, advanced microvascular or macrovascular complications, and extensive comorbid conditions and those with long-standing diabetes in whom the general goal is difficult to attain.

Special instructions

FPG: It is critical that samples for plasma glucose be spun soon after collection. SST tubes should be allowed to clot for about 30 minutes and centrifuged within 45 minutes of collection. If glucose samples are not centrifuged promptly, glucose levels will decrease factitiously.

Limitations

Hemoglobin A1c: Any cause of shortened erythrocyte survival will reduce exposure of erythrocytes to glucose with a consequent decrease in Hb A1c (%). Causes of shortened erythrocyte lifetime might be hemolytic anemia or other other hemolytic diseases, homozygous sickle cell trait, pregnancy, or recent significant or chronic blood loss. Glycated Hb F (fetal hemoglobin) is not detected as it does not contain the glycated beta chain that characterizes Hb A1c. Specimens containing high amounts of Hb F(>10%) may result in lower than expected Hb A1c.

LOINC map

Result codeResult nameUnitsResult LOINC
Glucose, Plasmamg/dL1558-6
Hemoglobin A1c%4548-4

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 82947, 83036

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation