Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Hemoglobin (Hb) A1c With eAG

Hemoglobin (Hb) A1c With eAG: Labcorp test 102525

Labcorp test 102525, CPT 83036. Specimen: Whole blood. Turnaround: Within 1 day.

Hemoglobin (Hb) A1c With eAG is Labcorp test code 102525, billed with CPT 83036. Specimen: Whole blood. Turnaround time: Within 1 day. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code102525
CPT83036
LOINC27353-2, 4548-4, 55399-0
SpecimenWhole blood
Volume4 mL
Minimum volume0.5 mL ( Note : This volume does not allow for repeat testing.) Pediatric EDTA whole blood tubes may be used. Please place original labeled capillary tube in a labeled transport tube for shipment to the laboratory.
ContainerLavender-top (EDTA) tube, green-top (lithium heparin) tube, or gray-top (sodium fluoride) tube
Turnaround timeWithin 1 day
Storage / transportMaintain specimen at room temperature.

Also known as: Hgb A 1c

Test includes

This test includes hemoglobin A 1c by immunoassay and estimated average glucose. Hemoglobin A 1c by immunoassay; estimated average glucose This test includes hemoglobin A 1c by immunoassay and estimated average glucose.

Use

Self-monitoring of blood glucose (SMBG) is one of the two primary techniques available for health providers and patients to assess the effectiveness of the management plan on glycemic control in diabetes. SMBG is typically carried out in the form of frequent fingerstick capillary glucose testing. Another more recent technology available is continuous glucose monitoring (CGM) carried out through a sensor that measures interstitial glucose concentration which correlates well with plasma glucose and capillary glucose levels. The second glycemic control technique is measurement of hemoglobin A 1c (Hb A 1c ). Because measurement of Hb A 1c is primary, the most accurate glycemic control tool…

Methodology

Roche Tina Quant

Collection instructions

The usual precautions in the collection of venipuncture samples should be observed. The sample must be free of clots. Samples with any hematocrit disorders can lead to erroneous results. Send the entire tube to the laboratory.

Stability

TemperaturePeriod
Room temperature3 days
Refrigerated7 days
Frozen6 months
Freeze/thaw cyclesStable x1
TemperaturePeriod
Room temperature14 days
Refrigerated14 days
Frozen14 days
Freeze/thaw cyclesStable x3
TemperaturePeriod
Room temperature3 days
Refrigerated7 days
Frozen6 months
Freeze/thaw cyclesStable x1

Causes for rejection

Clotted specimen; gross hemolysis

Limitations

Mean plasma glucose estimates outside of the 5.0% to 15.0% Hb A 1c range are not calculated since estimations in the nondiabetic range have not been verified. Only diabetic patients in stable control and without any suggestion of erythrocyte disorders were entered into the study. Children and pregnant women were also excluded; additional data in these groups are needed to confirm the established relationship. This mean plasma glucose calculation should only be used with Hb A 1c (001453). For additional information, see Hemoglobin (Hb) A1c [001453] .

LOINC map

Result codeResult nameUnitsResult LOINC
001481Hemoglobin A1c%4548-4
001472Estim. Avg Glu (eAG)mg/dL27353-2

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 83036

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation