Labcorp test 006718, CPT 86704. Specimen: Serum. Turnaround: 1 - 2 days.

Hepatitis B Core Antibody, Total is Labcorp test code 006718, billed with CPT 86704. Specimen: Serum. Turnaround time: 1 - 2 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories, Michigan Medicine Laboratories (MLabs).
LaboratoryLabcorp
CLIA number34D0655059
Test code006718
CPT86704
LOINC13952-7
SpecimenSerum
Volume1 mL
Minimum volume0.4 mL ( Note: This volume does not allow for repeat testing.)
ContainerGel-barrier tube, red-top tube or serum transfer tube
Turnaround time1 - 2 days
Storage / transportRoom temperature

Also known as: Anti-HBc; Antibody to Hepatitis B Core Antigen; Core Antibody; HBV

Use

This assay can be used as an aid in the diagnosis of individuals with acute or chronic hepatitis B virus (HBV) infection and in the determination of the clinical status of HBV infected individuals in conjunction with other HBV serological markers associated with HBV infection. This assay can also be used as an aid in the differential diagnosis in individuals displaying signs of hepatitis in whom etiology is unknown.

Methodology

Immunochemiluminometric assay (ICMA)

Collection instructions

If tube other than a gel-barrier tube is used, transfer separated serum to a screw-cap polypropylene transport tube. Do not freeze gel-barrier tube (pour off serum first).

Stability

TemperaturePeriod
Room temperature7 days (stability provided by manufacturer or literature reference)
Refrigerated14 days
Frozen14 days
Freeze/thaw cyclesStable x3

Causes for rejection

Gross hemolysis, obvious microbial contamination, and/or received outside of specimen and/or storage and/or labeling requirements; heat-inactivated samples; cadaveric samples

Reference range

Negative

Special instructions

This test may exhibit interference when sample is collected from a person who is consuming a supplement with a high dose of biotin (also termed as vitamin B7 or B8, vitamin H, or coenzyme R). It is recommended to ask all patients who may be indicated for this test about biotin supplementation. Patients should be cautioned to stop biotin consumption at least 72 hours prior to the collection of a sample.

Limitations

The results from this or any other diagnostic kit should be used and interpreted only in the context of the overall clinical picture. A negative test result does not exclude the possibility of exposure to hepatitis B virus. Levels of anti-HBc may be undetectable both in early infection and later after infection. This is a qualitative assay; reported antibody level cannot be correlated to an endpoint titer. Assay performance characteristics have not been established for immunocompromised or immunosuppressed patients.

LOINC map

Result codeResult nameUnitsResult LOINC
006718Hep B Core Ab, Tot13952-7

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 86704

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation