Labcorp test 144025, CPT 86704, 86706, 86803, 87340. Specimen: Serum. Turnaround: 1 - 3 days.

Viral Hepatitis Screening and Diagnosis (HBV, HCV) is Labcorp test code 144025, billed with CPT 86704, 86706, 86803, 87340. Specimen: Serum. Turnaround time: 1 - 3 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories, Michigan Medicine Laboratories (MLabs).
LaboratoryLabcorp
CLIA number34D0655059
Test code144025
CPT86704; 86706; 86803; 87340
LOINC13952-7, 22322-2, 5196-1, 92889-5, 95235-8
SpecimenSerum
Volume4 mL
Minimum volume2 mL ( Note: This volume does not allow for repeat testing.)
ContainerGel-barrier tube or serum transfer tube
Turnaround time1 - 3 days
Storage / transportRefrigerated (preferred) HBV: stable 14 days at room temperature, refrigerated (preferred), and frozen HCV: stable 24 hours at room temperature, 6 days refrigerated or 6 weeks frozen

Test includes

Hepatitis B Surface Antigen (HBsAg) Screen, Qualitative [006510]; Hepatitis B Surface Antibody, Qualitative [006395]; Hepatitis B Core Antibody, Total with reflex to IgM [160101]; Hepatitis C Virus (HCV) Antibody with reflex to Quantitative Real-time PCR [144050]

Use

This test is used to aid in the diagnosis of viral hepatitis due to infection with HBV and/or HCV.

Methodology

Immunochemiluminometric assay (ICMA) (see individual tests for methodologies)

Collection instructions

Centrifuge sample within 24 hours of collection. If tube other than a gel-barrier tube is used, or if sample will be shipped frozen, transfer separated serum to a screw-cap polypropylene transport tube. Do not freeze gel-barrier tube (pour off serum first).

Causes for rejection

Heat-inactivated specimens; cord blood; cadaveric specimens; or body fluids other than serum or EDTA plasma; gross hemolysis; excessive lipemia; improper labeling; frozen gel-barrier tube

Special instructions

If reflex test is performed, additional charges/CPT code(s) may apply. This test may exhibit interference when sample is collected from a person who is consuming a supplement with a high dose of biotin (also termed as vitamin B7 or B8, vitamin H, or coenzyme R). It is recommended to ask all patients who may be indicated for this test about biotin supplementation. Patients should be cautioned to stop biotin consumption at least 72 hours prior to the collection of a sample.

Limitations

The assays in this panel have not been FDA cleared or approved for the screening of blood or plasma donors. Assay performance characteristics have not been established for immunocompromised or immunosuppressed patients, cord blood or patients less than 2 years of age. The performance characteristics of this assay have not been determined for use in cadaveric specimens.

LOINC map

Result codeResult nameUnitsResult LOINC
006510HBsAg Screen5196-1
006408Hep B Surface Ab, Qual22322-2
006718Hep B Core Ab, Tot13952-7
006724HBV Interpretation95235-8

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 86704, 86706, 86803

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation