Labcorp test 182923, CPT 87186. Specimen: Slowly-growing mycobacteria, other than M. tuberculosis or M. avium , isolated from a primary clinical specimen, on a su. Turnaround: 35 - 40 days.

Nontuberculous Slowly-growing Mycobacterium Susceptibility−Broth Dilution is Labcorp test code 182923, billed with CPT 87186. Specimen: Slowly-growing mycobacteria, other than M. tuberculosis or M. avium , isolated from a primary clinical specimen, on a submitted AFB conventi. Turnaround time: 35 - 40 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code182923
CPT87186
LOINC185-9, 189-1, 29579-0, 40699-1
SpecimenSlowly-growing mycobacteria, other than M. tuberculosis or M. avium , isolated from a primary clinical specimen, on a submitted AFB conventional solid medium, or an AFB broth medium
VolumePure culture isolate on an AFB conventional solid medium or a minimum of 1 mL of AFB broth medium
ContainerConventional or broth medium, tightly sealed, in etiologic agent packaging
Turnaround time35 - 40 days
Storage / transportMaintain media at room temperature.

Also known as: M kansasii Susceptibility Testing; AFB Susceptibility Testing; MOTT Susceptibility Testing; Slow-grower Susceptibility Testing

Test includes

Susceptibility testing for amikacin, ciprofloxacin, clarithromycin, doxycycline, linezolid, minocycline, moxifloxacin, rifabutin, rifampin, streptomycin and trimethoprim/sulfamethoxazole

Use

Determine the susceptibility of nontuberculous slowly-growing mycobacterial isolates to a profile of antimycobacterial agents. Clinical breakpoints for M. kansasii and Nontuberculosis Mycobacteria other than M. avium Complex are the same. Some fastidious isolates may not exhibit adequate growth for susceptibility testing ( M. genvense, M. haemophilum ). Others such as M. gordonae are rarely clinically relevant and susceptibility testing is not recommended. If patients are not responding to several months of therapy, repeat susceptibility testing is recommended.

Methodology

Sensititre® broth microdilution (MIC)

Causes for rejection

Specimen received in leaking or in broken transport tube or vial; specimen received in expired transport medium; mixed culture; unlabeled culture or name discrepancy between specimen and request label

Limitations

Susceptibilities cannot be reported if the organism fails to grow in the test medium. Susceptibilities cannot be performed on mixed cultures. An organism identification is required prior to reporting susceptibility results. This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.

LOINC map

Result codeResult nameUnitsResult LOINC
182924Organism ID40699-1
5-Dec182923Slow Grower Broth Suscep.29579-0
182923Slow Grower Broth Suscep.29579-0
182923Slow Grower Broth Suscep.29579-0

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 87186

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation