Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Nocardia, Aerobic Actinomycetes Susceptibility (AST)−Broth Dilution

Nocardia, Aerobic Actinomycetes Susceptibility (AST)−Broth Dilution: Labcorp test 182857

Labcorp test 182857, CPT 87186. Specimen: Nocardia species or other aerobic actinomycetes isolated from a primary clinical specimen, on a submitted conventional s. Turnaround: 14 - 28 days.

Nocardia, Aerobic Actinomycetes Susceptibility (AST)−Broth Dilution is Labcorp test code 182857, billed with CPT 87186. Specimen: Nocardia species or other aerobic actinomycetes isolated from a primary clinical specimen, on a submitted conventional solid medium (ie, Low. Turnaround time: 14 - 28 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code182857
CPT87186
LOINC141-2, 20-8, 43365-6, 50545-3
SpecimenNocardia species or other aerobic actinomycetes isolated from a primary clinical specimen, on a submitted conventional solid medium (ie, Lowenstein-Jensen [LJ] slant, Sabouraud dextrose [SAB] slant, or similar)
VolumePure culture isolate on a conventional solid medium
ContainerConventional medium, tightly sealed, in etiologic agent packaging
Turnaround time14 - 28 days
Storage / transportMaintain media at room temperature.

Also known as: Nocardia Susceptibility Testing; AFB Susceptibility Testing; Susceptibility Testing, Nocardia

Test includes

Susceptibility testing for amikacin, amoxicillin/clavulanic acid, ceftriaxone, ciprofloxacin, clarithromycin, doxycycline, imipenem, linezolid, minocycline, moxifloxacin, trimethoprim/sulfamethoxazole, and tobramycin. MIC values will be reported with CLSI interpretive comments.

Use

Determine the susceptibility of Nocardia species and/or other aerobic Actinomycetes isolates to a profile of antimicrobial agents. Routine susceptibility testing of Nocardia isolates is recommended since the Nocardia genus contains a heterogeneous group of organisms that has variable antibiotic susceptibilities.

Methodology

Sensititre® broth microdilution (MIC)

Causes for rejection

Broken transport tube or vial; specimen received in expired transport medium; mixed culture; unlabeled culture or name discrepancy between specimen and request label

Limitations

Susceptibilities cannot be reported if the organism fails to grow in the test medium. Susceptibilities cannot be performed on mixed cultures. This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.

LOINC map

Result codeResult nameUnitsResult LOINC
182858Organism ID43365-6
5-Dec182857Nocardia Susceptibility Broth50545-3
182857Nocardia Susceptibility Broth50545-3
182857Nocardia Susceptibility Broth50545-3

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 87186

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation