Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Mycobacterium avium Complex Susceptibility−Broth Dilution

Mycobacterium avium Complex Susceptibility−Broth Dilution: Labcorp test 182832

Labcorp test 182832, CPT 87186. Specimen: Mycobacterium avium complex isolated from a primary clinical specimen, on a submitted AFB conventional solid medium, or . Turnaround: 21 - 30 days.

Mycobacterium avium Complex Susceptibility−Broth Dilution is Labcorp test code 182832, billed with CPT 87186. Specimen: Mycobacterium avium complex isolated from a primary clinical specimen, on a submitted AFB conventional solid medium, or an AFB broth medium. Turnaround time: 21 - 30 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code182832
CPT87186
LOINC185-9, 189-1, 29576-6, 40699-1
SpecimenMycobacterium avium complex isolated from a primary clinical specimen, on a submitted AFB conventional solid medium, or an AFB broth medium
VolumePure culture isolate on an AFB conventional solid medium or a minimum of 1 mL of AFB broth medium
ContainerConventional or broth medium, tightly sealed, in etiologic agent packaging
Turnaround time21 - 30 days
Storage / transportMaintain media at room temperature.

Also known as: AFB Susceptibility Testing; M avium Complex Susceptibility Testing; MAC Susceptibility Testing

Test includes

Susceptibility testing for amikacin, ciprofloxacin, clarithromycin, doxycycline, moxifloxacin, rifabutin, rifampin, streptomycin and trimethoprim/sulfamethoxazole. MIC values will be reported with CLSI interpretive comments, if available.

Use

Determine the susceptibility of Mycobacterium avium complex isolates to a profile of antimycobacterial agents. Testing is recommended for isolates from patients with previous macrolide therapy, patients who relapse while on macrolide therapy, or patients with initial isolates from blood, tissue, or clinically relevant respiratory specimens. Repeat susceptibility is recommended after 3 months (disseminated disease) or 6 months (chronic pulmonary disease) if the cultures are still positive or if there is no clinical improvement. First line drugs for M. avium complex treatment includes clarithromycin and amikacin (IV or inhaled). Clarithromycin is the most appropriate class drug for the…

Methodology

Sensititre® broth microdilution (MIC)

Causes for rejection

Specimen received in leaking or in broken transport tube or vial; specimen received in expired transport medium; mixed culture; unlabeled culture or name discrepancy between specimen and request label

Limitations

Susceptibilities cannot be reported if the organism fails to grow in the test medium. Susceptibilities cannot be performed on mixed cultures. This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.

LOINC map

Result codeResult nameUnitsResult LOINC
182831Organism ID40699-1
5-Dec182832MAC Susceptibility Broth29576-6
182832MAC Susceptibility Broth29576-6
182832MAC Susceptibility Broth29576-6

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 87186

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation