Vaginitis Plus (VG+), NuSwab® (Women's Health): Labcorp test 180021
Labcorp test 180021, CPT 87491, 87591, 87661, 87798, 87801. Specimen: Vaginal swab. Turnaround: 3 - 4 days.
Use
This test is intended to be used as an aid to the diagnosis of bacterial vaginosis (BV) in women with a clinical presentation consistent with this disorder. The BV test utilizes semiquantitative PCR analysis of the three most predictive marker organisms ( Atopobium vaginae, BVAB-2, and Megasphaera -1) to generate a total score that correlates directly with the presence or absence of BV. In this test system, samples with a total score of 0 to 1 are considered negative for BV, samples with a score of 3 to 6 are positive for BV, and samples with a score of 2 are indeterminate for BV. Used to detect the presence of Candida albicans and Candida glabrata DNA in vaginal samples as an aid to the…
Methodology
Nucleic acid amplification (NAA)
Collection instructions
Vaginal swab: Collect vaginal fluid sample using the Aptima® swab by contacting the swab to the lower third of the vaginal wall and rotating the swab for 10 to 30 seconds to absorb fluid. Immediately place the swab into the transport tube and carefully break the swab shaft against the side of the tube. Tightly screw on the cap.
Stability
| Temperature | Period |
|---|---|
| Room temperature | 30 days |
| Refrigerated | 30 days |
| Frozen | Not acceptable |
Causes for rejection
Specimen with incorrect patient identification; unlabeled specimen; inappropriate specimen transport conditions, including specimens received frozen; specimens received after prolonged delay (usually >72 hours); specimen leaked in transit; specimen in expired transport or incorrect transport device; specimens with inappropriate source for test requested; specimen with fixative or additives; Aptima® urine transport; Aptima® swab transport >30 days from collection; Aptima® swab specimen without a swab; cleaning swab (white-shaft swab) in Aptima® swab transport; any non-Aptima® swab submitted in Aptima® transport device; transport device with multiple swabs; bloody or grossly mucoid specimens; bacterial swabs; specimen in ProbeTec™ UPT transport; ProbeTec™ Q-swabs
Limitations
This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration. The FDA has determined that such clearance or approval is not necessary.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 180061 | Atopobium vaginae | Score | 69565-0 |
| 180062 | BVAB 2 | Score | 69566-8 |
| 180063 | Megasphaera 1 | Score | 69567-6 |
| 019054 | 11502-2 | ||
| 180056 | Candida albicans, NAA | 69562-7 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 87491, 87591, 87661
- Bacterial Vaginosis (Sialidase), Chlamydia trachomatis, Neisseria gonorrhoeae, Trichomonas vaginalis, NAA, Vaginal Yeast Culture
- Chlamydia trachomatis and Neisseria gonorrhoeae (CTNG) by Transcription-Mediated Amplification (TMA) with Reflex to CT/NG Confirmation
- Chlamydia trachomatis by Transcription-Mediated Amplification (TMA)
- Chlamydia trachomatis L serovars (LGV) by PCR
- Chlamydia trachomatis, Conjunctival Swab, NAA
- Chlamydia trachomatis, NAA
- Chlamydia trachomatis, Neisseria gonorrhoeae and Trichomonas vaginalis, NAA
- Chlamydia trachomatis, Neisseria gonorrhoeae, and Herpes Simplex Virus (HSV) Types 1 and 2, NAA
- Chlamydia trachomatis, Neisseria gonorrhoeae, Trichomonas vaginalis, and Herpes Simplex Virus (HSV) Types 1 and 2, NAA
- Chlamydia trachomatis, Pharyngeal Swab, NAA
- Chlamydia trachomatis, Rectal Swab, NAA
- Chlamydia/Gonococcus − Client-provided Aliquot
- Chlamydia/Gonococcus, NAA
- Chlamydia/Gonococcus, NAA With Confirmation
- Chlamydia/Gonococcus, NAA With Reflex to Trichomonas vaginalis, NAA
- Chlamydia/Gonococcus, Pharyngeal Swab, NAA
- Chlamydia/Gonococcus, Rectal Swab, NAA
- Chlamydia/Gonococcus/Genital Mycoplasma Profile, NAA, Swab
- Chlamydia/Gonococcus/Genital Mycoplasma Profile, NAA, Urine
- Chlamydia/Gonococcus/Mycoplasma genitalium (With Reflex to Macrolide Resistance), NAA, Swab
- Chlamydia/Gonococcus/Mycoplasma genitalium (With Reflex to Macrolide Resistance), NAA, Urine
- Chlamydia/Gonococcus/Mycoplasma genitalium, NAA, Swab
- Chlamydia/Gonococcus/Mycoplasma genitalium, NAA, Urine
- Chlamydia/Gonococcus/Trichomonas vaginalis/Mycoplasma genitalium (With Reflex to Macrolide Resistance), NAA, Swab
- Chlamydia/Gonococcus/Trichomonas vaginalis/Mycoplasma genitalium (With Reflex to Macrolide Resistance), NAA, Urine
- Chlamydia/Gonococcus/Trichomonas vaginalis/Mycoplasma genitalium, NAA, Swab
- Chlamydia/Gonococcus/Trichomonas vaginalis/Mycoplasma genitalium, NAA, Urine
- Genital Ulcer Disease Panel by PCR
- Gynecologic Pap Test (Image-guided), Liquid-based Preparation and Chlamydia trachomatis, NAA
- Gynecologic Pap Test (Image-guided), Liquid-based Preparation and Chlamydia/Gonococcus and Herpes Simplex Virus (HSV) Types 1 and 2, NAA
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.