Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Ehrlichia chaffeensis (HME) Antibody, IgG and IgM, IFA

Ehrlichia chaffeensis (HME) Antibody, IgG and IgM, IFA: Labcorp test 164680

Labcorp test 164680, CPT 86666. Specimen: Serum. Turnaround: 2 - 5 days.

Ehrlichia chaffeensis (HME) Antibody, IgG and IgM, IFA is Labcorp test code 164680, billed with CPT 86666. Specimen: Serum. Turnaround time: 2 - 5 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code164680
CPT86666(x2)
LOINC48850-2
SpecimenSerum
Volume0.4 mL
Minimum volume0.2 mL
ContainerGel-barrier tube, red-top tube or serum transfer tube
Turnaround time2 - 5 days
Storage / transportRoom temperature

Also known as: Ehrlichia; HME; Tickborne

Use

This test is used for detection and semiquantitation of serum IgG and IgM antibodies to Ehrlichia chaffeensis to aid in the diagnosis of human monocytic ehrlichiosis (HME). Confirmation of diagnosis is based on laboratory testing, but antibiotic therapy should not be delayed in patients with a suggestive clinical presentation. The diagnosis of acute ehrlichiosis cannot be confirmed solely by the presence of antibodies in a serum sample collected at a single timepoint. DNA PCR can be used to diagnose acute infection. Demonstration of a 4-fold rise in IgG-specific antibody titers by IFA in paired samples (acute and convalescent) confirms infection with E. chaffeensis. IgM antibodies are less…

Methodology

Indirect fluorescent antibody (IFA)

Collection instructions

If tube other than a gel-barrier tube is used, transfer separated serum to a labeled plastic transport tube. Do not freeze gel-barrier tube; pour off serum first.

Stability

TemperaturePeriod
Room temperature14 days
Refrigerated14 days
Frozen14 days
Freeze/thaw cyclesStable x4

Causes for rejection

Hemolysis; lipemia; gross bacterial contamination; frozen gel-barrier tube

Reference range

• IgG negative: <1:64 • IgM negative: <1:20

Limitations

The diagnosis of acute ehrlichiosis cannot be confirmed solely by the presence of Ehrlichia antibody in a serum sample collected at a single time point.

LOINC map

Result codeResult nameUnitsResult LOINC
Ehrlichia chaffeensis Ab164704E. chaffeensis IgM48850-2

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 86666

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation