Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › ARUP Laboratories › Ehrlichia chaffeensis Antibody, IgG by IFA

Ehrlichia chaffeensis Antibody, IgG by IFA: ARUP Laboratories test 0051004

ARUP Laboratories test 0051004, CPT 86666. Specimen: Serum Separator Tube.. Turnaround: 1-5 days.

Ehrlichia chaffeensis Antibody, IgG by IFA is ARUP Laboratories test code 0051004, billed with CPT 86666. Specimen: Serum Separator Tube.. Turnaround time: 1-5 days. Performing laboratory: ARUP Laboratories, CLIA 46D0523979 (Salt Lake City, UT). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, Labcorp.
LaboratoryARUP Laboratories
CLIA number46D0523979
Test code0051004
CPT86666
LOINC47405-6
SpecimenSerum Separator Tube.
Turnaround time1-5 days
Storage / transportRefrigerated.

Also known as: HME (Human Monocytic Ehrlichiosis); Tick Borne Diseases; E. Chaffeensis

Use

Most useful to detect antibodies during convalescent phase of disease. PCR testing is preferred; refer to Tick-Borne Disease Panel by PCR, Blood ( 2008670 ) or Ehrlichia and Anaplasma Species by PCR ( 2007862 ).

Methodology

Semi-Quantitative Indirect Fluorescent Antibody (IFA)

Collection instructions

Separate from cells ASAP or within 2 hours of collection. Transfer 1 mL serum to an ARUP standard transport tube. (Min: 0.4 mL) Parallel testing is preferred and convalescent specimens must be received within 30 days from receipt of the acute specimens. Mark specimens plainly as acute or convalescent.

Stability

After separation from cells: Ambient: 48 hours; Refrigerated: 2 weeks; Frozen: 1 year (avoid repeated freeze/thaw cycles)

Causes for rejection

Contaminated, hemolyzed, or severely lipemic specimens.

Reference range

< 1:64 Negative-No significant level of Ehrlichia chaffeensis IgG antibody detected. 1:64-1:128 Equivocal-Questionable presence of Ehrlichia chaffeensis IgG antibody detected. Repeat testing in 10-14 days may be helpful. ≥1:256 Positive-Presence of IgG antibody to Ehrlichia chaffeensis detected, suggestive of current or past infection.

Performed

Tue, Fri

Compliance Category

Laboratory Developed Test (LDT)

New York DOH Approval Status

This test is New York state approved.

LOINC map

Result codeResult nameUnitsResult LOINC
0051004Ehrlichia chaffeensis Antibody, IgG47405-6

View this test on ARUP Laboratories's website → · Last checked 2026-11-29

Other tests billed with CPT 86666

Search the National Lab Test Directory · All ARUP Laboratories tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation