Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Anaplasma phagocytophilum (HGE) Antibody, IgG and IgM, IFA

Anaplasma phagocytophilum (HGE) Antibody, IgG and IgM, IFA: Labcorp test 164672

Labcorp test 164672, CPT 86666. Specimen: Serum. Turnaround: 2 - 5 days.

Anaplasma phagocytophilum (HGE) Antibody, IgG and IgM, IFA is Labcorp test code 164672, billed with CPT 86666. Specimen: Serum. Turnaround time: 2 - 5 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code164672
CPT86666(x2)
LOINC23877-4, 23878-2, 55150-7
SpecimenSerum
Volume0.4 mL
Minimum volume0.2 mL
ContainerRed-top tube or gel-barrier tube or serum transfer tube
Turnaround time2 - 5 days
Storage / transportRefrigerate.

Also known as: Anaplasma phagocytophilum; Ehrlichia; HGE; Tickborne

Use

This test is used for detection and semiquantitation of serum IgG and IgM antibodies to Anaplasma phagocytophilum (HGE) to aid in the diagnosis of human granulocytic ehrlichiosis. Confirmation of diagnosis is based on laboratory testing, but antibiotic therapy should not be delayed in patients with a suggestive clinical presentation. The diagnosis of acute anaplasmosis cannot be confirmed solely by the presence of antibodies in a serum sample collected at a single timepoint. DNA PCR can be used to diagnose acute infection. Demonstration of a 4-fold rise in IgG-specific antibody titers by IFA in paired samples (acute and convalescent) confirms infection with A. phagocytophilum. IgM…

Methodology

Indirect fluorescent antibody (IFA)

Collection instructions

Specimen should be free of bacterial contamination, hemolysis, and lipemia.

Causes for rejection

Hemolysis; lipemia; gross bacterial contamination

Reference range

• IgG negative: <1:64 • IgM negative: <1:64

Limitations

The diagnosis of acute anaplasmosis cannot be confirmed solely by the presence of Anaplasma antibody in a serum sample collected at a single time point.

LOINC map

Result codeResult nameUnitsResult LOINC
164674A. phagocytophilum IgG23877-4
164667A. phagocytophilum IgM23878-2

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 86666

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation