Ferritin (Women's Health): Labcorp test 004598
Labcorp test 004598, CPT 82728. Specimen: Serum (preferred) or plasma. Turnaround: Within 1 day.
Use
This test is used to diagnose iron deficiency and iron-overload conditions. Ferritin levels correlate with and are useful in evaluation of total body iron storage. In hemochromatosis, both ferritin and iron saturation are increased. Ferritin levels in hemochromatosis may be >1000 ng/mL.
Methodology
Electrochemiluminescence immunoassay (ECLIA) This assay is performed on the Roche cobas instrument in multiple laboratories throughout Labcorp.
Collection instructions
If a red-top tube or plasma is used, transfer separated serum or plasma to a plastic transport tube.
Stability
| Temperature | Period |
|---|---|
| Room temperature | 14 days |
| Refrigerated | 14 days |
| Frozen | 14 days |
| Freeze/thaw cycles | Stable x3 |
Causes for rejection
Citrate plasma specimen; improper labeling
Reference range
See table. Age Male (ng/mL) Female (ng/mL) 0 to 9 d 20−273 20−129 10 to 30 d 20−273 20−111 31 to 60 d 20−273 20−154 61 to 120 d 20−273 20−211 121 to 150 d 20−95 20−102 151 to 365 d 20−95 20−110 1 to 5 y 20−64 20−71 6 to 11 y 20−77 20−79 12 to 19 y 30−124 30−77 20 to 40 y 30−400 30−150 41 to 45 y 30−400 30−184 46 to 49 y 30−400 30−216 50 to 51 y 30−400 30−232 52 to 55 y 30−400 30−265 56 to 58 y 30−400 30−280 59 to 64 y 30−400 30−327 65 to 80 y 30−400 30−365 >80 y 30−400 30−397
Special instructions
Values obtained with different assay methods should not be used interchangeably in serial testing. It is recommended that only one assay method be used consistently to monitor each patient's course of therapy. This procedure does not provide serial monitoring; it is intended for one-time use only. If serial monitoring is required, please order Ferritin (Serial Monitor) [480111] . This test may exhibit interference when sample is collected from a person who is consuming a supplement with a high dose of biotin (also termed as vitamin B7 or B8, vitamin H, or coenzyme R). It is recommended to ask all patients who may be indicated for this test about biotin supplementation. Patients should be cautioned to stop biotin consumption at least 72 hours prior to the collection of a sample.
Limitations
Ferritin is an acute-phase reactant and thus may be increased in people with inflammation, liver disease, chronic infection, autoimmune disorders, and some types of cancer. Ferritin measurement is of limited usefulness during pregnancy because it diminishes late in pregnancy, even when bone marrow iron is present. As with all tests containing monoclonal mouse antibodies, erroneous findings may be obtained from samples taken from patients who have been treated with monoclonal mouse antibodies or have received them for diagnostic purposes. In rare cases, interference due to extremely high titers of antibodies to streptavidin and ruthenium can occur.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 004598 | Ferritin | ng/mL | 2276-4 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 82728
- Anemia Profile B
- Chronic Fatigue Profile
- COVID-19 Poor Outcomes Risk Profile
- COVID-19 Severe Disease Progression Risk Profile
- Ferritin
- Ferritin
- Ferritin
- Ferritin (Serial Monitor)
- Hemoglobinopathy Fractionation Cascade With Reflex to α-Thalassemia
- Liver Fibrosis, Non-Alcoholic Fatty Liver Disease (Echosens)
- Long COVID Profile
- Post-Bariatric Surgery Comprehensive Profile
- Post-Bariatric Surgery Micronutrient Profile
- Pre-Bariatric Surgery Comprehensive Profile
- Pre-Bariatric Surgery Micronutrient Profile
- Anemia Profile B
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation