Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Cancer Antigen (CA) 125 in the Presence of Human Antimouse Antibodies (HAMA)

Cancer Antigen (CA) 125 in the Presence of Human Antimouse Antibodies (HAMA): Labcorp test 144733

Labcorp test 144733, CPT 86304. Specimen: Serum. Turnaround: 4 - 5 days.

Cancer Antigen (CA) 125 in the Presence of Human Antimouse Antibodies (HAMA) is Labcorp test code 144733, billed with CPT 86304. Specimen: Serum. Turnaround time: 4 - 5 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, Michigan Medicine Laboratories (MLabs), ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code144733
CPT86304
LOINC10334-1
SpecimenSerum
Volume1 mL
Minimum volume0.5 mL ( Note: This volume does not allow for repeat testing.)
ContainerRed-top tube or gel-barrier tube
Turnaround time4 - 5 days
Storage / transportRoom temperature; stable at room temperature or refrigerated for 14 days.

Also known as: CA-125 in the Presence of HAMA

Use

Eliminate interference from HAMA in the CA 125 assay to help monitor disease progression in nonmucinous epithelial neoplasms of the ovary. This test is performed in the same way as the Cancer Antigen (CA) 125 test except that the interference from HAMA present in the specimen is eliminated by use of a blocking reagent.

Methodology

Electrochemiluminescence immunoassay (ECLIA)

Collection instructions

If a red-top tube is used, transfer separated serum to a plastic transport tube.

Patient preparation

It is suggested that the assay not be performed until at least three weeks after the completion of primary chemotherapy and at least two months following abdominal surgery.

Causes for rejection

Citrate plasma specimen; improper labeling

Reference range

• Female: 0.0−38.1 units/mL • Male: Not established

Special instructions

A blocking agent is used to remove interference from HAMA (human antimouse antibodies) in the CA 125 assay. For a complete test description, see Cancer Antigen (CA) 125 [002303] . This test may exhibit interference when sample is collected from a person who is consuming a supplement with a high dose of biotin (also termed as vitamin B7 or B8, vitamin H, or coenzyme R). It is recommended to ask all patients who may be indicated for this test about biotin supplementation. Patients should be cautioned to stop biotin consumption at least 72 hours prior to the collection of a sample.

Limitations

CA 125 is not specific for tumors of the ovary and cannot distinguish benign from malignant tumors. It is not a screening test.

LOINC map

Result codeResult nameUnitsResult LOINC
144738CA 125 in the Presence of HAMAU/mL10334-1

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 86304

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation