Cancer Antigen (CA) 125: Labcorp test 002303

Labcorp test 002303, CPT 86304. Specimen: Serum. Turnaround: Within 1 day.

Cancer Antigen (CA) 125 is Labcorp test code 002303, billed with CPT 86304. Specimen: Serum. Turnaround time: Within 1 day. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, Michigan Medicine Laboratories (MLabs), ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code002303
CPT86304
LOINC10334-1
SpecimenSerum
Volume1 mL
Minimum volume0.7 mL ( Note: This volume does not allow for repeat testing.)
ContainerGel-barrier tube (preferred) or red-top tube
Turnaround timeWithin 1 day
Storage / transportRoom temperature

Also known as: CA-125, Second Generation Assay

Use

The Elecsys CA 125 II assay is labeled "For in vitro diagnostic use" in the manufacturer's package insert.

Methodology

Electrochemiluminescence immunoassay (ECLIA)

Collection instructions

If a red-top tube is used, transfer separated serum to a plastic transport tube.

Stability

TemperaturePeriod
Room temperature14 days
Refrigerated14 days
Frozen14 days
Freeze/thaw cyclesStable x3

Patient preparation

It is suggested that the assay not be performed until at least three weeks after the completion of primary chemotherapy and at least two months following abdominal surgery.

Causes for rejection

Citrate plasma specimen; improper labeling

Reference range

• Female: 0.0−38.1 units/mL • Male: Not established

Special instructions

Values obtained with different assay methodologies should not be used interchangeably in serial testing. It is recommended that only one assay method be used consistently to monitor a patient's course of therapy. This procedure does not provide serial monitoring; it is intended for one-time use only. If serial monitoring is required, please use the serial monitoring number 480061 to order. This test may exhibit interference when sample is collected from a person who is consuming a supplement with a high dose of biotin (also termed as vitamin B7 or B8, vitamin H, or coenzyme R). It is recommended to ask all patients who may be indicated for this test about biotin supplementation. Patients should be cautioned to stop biotin consumption at least 72 hours prior to the collection of a sample.

Limitations

The measured CA 125 value of a patient's sample can vary depending on the test procedure used. The laboratory finding must, therefore, always contain a statement on the CA 125 assay method used. CA 125 values determined on patient samples by different test procedures cannot be directly compared with one another and could cause erroneous medical interpretations. As with all tests containing monoclonal mouse antibodies, erroneous findings may be obtained from samples taken from patients who have been treated with monoclonal mouse antibodies or have received them for diagnostic purposes. In rare cases, interference due to extremely high titers of antibody to streptavidin and ruthenium can…

LOINC map

Result codeResult nameUnitsResult LOINC
002321Cancer Antigen (CA) 125U/mL10334-1

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 86304

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation