Cancer Antigen (CA) 125 (Women's Health): Labcorp test 002303
Labcorp test 002303, CPT 86304. Specimen: Serum. Turnaround: Within 1 day.
Also known as: CA-125, Second Generation Assay
Use
The Elecsys CA 125 II assay is labeled "For in vitro diagnostic use" in the manufacturer's package insert.
Methodology
Electrochemiluminescence immunoassay (ECLIA)
Collection instructions
If a red-top tube is used, transfer separated serum to a plastic transport tube.
Stability
| Temperature | Period |
|---|---|
| Room temperature | 14 days |
| Refrigerated | 14 days |
| Frozen | 14 days |
| Freeze/thaw cycles | Stable x3 |
Patient preparation
It is suggested that the assay not be performed until at least three weeks after the completion of primary chemotherapy and at least two months following abdominal surgery.
Causes for rejection
Citrate plasma specimen; improper labeling
Reference range
• Female: 0.0−38.1 units/mL • Male: Not established
Special instructions
Values obtained with different assay methodologies should not be used interchangeably in serial testing. It is recommended that only one assay method be used consistently to monitor a patient's course of therapy. This procedure does not provide serial monitoring; it is intended for one-time use only. If serial monitoring is required, please use the serial monitoring number 480061 to order. This test may exhibit interference when sample is collected from a person who is consuming a supplement with a high dose of biotin (also termed as vitamin B7 or B8, vitamin H, or coenzyme R). It is recommended to ask all patients who may be indicated for this test about biotin supplementation. Patients should be cautioned to stop biotin consumption at least 72 hours prior to the collection of a sample.
Limitations
The measured CA 125 value of a patient's sample can vary depending on the test procedure used. The laboratory finding must, therefore, always contain a statement on the CA 125 assay method used. CA 125 values determined on patient samples by different test procedures cannot be directly compared with one another and could cause erroneous medical interpretations. As with all tests containing monoclonal mouse antibodies, erroneous findings may be obtained from samples taken from patients who have been treated with monoclonal mouse antibodies or have received them for diagnostic purposes. In rare cases, interference due to extremely high titers of antibody to streptavidin and ruthenium can…
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 002321 | Cancer Antigen (CA) 125 | U/mL | 10334-1 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 86304
- CA 125
- CA 125
- Cancer Antigen (CA) 125
- Cancer Antigen (CA) 125 (Serial Monitor)
- Cancer Antigen (CA) 125 in the Presence of Human Antimouse Antibodies (HAMA)
- Cancer Antigen 125
- Ovarian Cancer Monitor
- Risk of Ovarian Malignancy Algorithm
- ROMA score
- Ovarian Cancer Monitor
Search the National Lab Test Directory · All Labcorp tests and CLIA locations