West Nile Virus RNA, Qualitative, PCR: Labcorp test 140242

Labcorp test 140242, CPT 87798. Specimen: Plasma (preferred) or serum. Turnaround: 3 - 4 days.

West Nile Virus RNA, Qualitative, PCR is Labcorp test code 140242, billed with CPT 87798. Specimen: Plasma (preferred) or serum. Turnaround time: 3 - 4 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Michigan Medicine Laboratories (MLabs), Cleveland Clinic Laboratories, ARUP Laboratories, Quest Diagnostics.
LaboratoryLabcorp
CLIA number34D0655059
Test code140242
CPT87798
LOINC34460-6
SpecimenPlasma (preferred) or serum
Volume1 mL
Minimum volume0.5 mL ( Note: This volume does not allow for repeat testing.)
ContainerLavender-top (EDTA) tube or gel-barrier tube
Turnaround time3 - 4 days
Storage / transportRefrigerate.

Also known as: Flavivirus; Vector-Borne; Mosquito-Borne; WNV PCR

Use

This test is indicated for use as an aid to the diagnosis of West Nile virus in plasma or serum. West Nile virus PCR is useful for detecting viremia in immunocompromised patients who may have prolonged viremia and delayed antibody responses, as well as patients who are on B-cell depleting immunotherapies.

Methodology

Polymerase chain reaction (PCR)

Collection instructions

Usual blood collection technique; do not freeze serum gel tubes; send to lab refrigerated (preferred)

Stability

TemperaturePeriod
Room temperature24 hours
Refrigerated7 days
Frozen30 days
Freeze/thaw cyclesStable x2

Causes for rejection

Frozen SST or blood; heparin tube; improper labeling; gross specimen contamination, improper storage of transport; specimen too old; leaking or broken tube

Limitations

A negative test does not rule out infection with West Nile virus. Results should be interpreted in conjunction with clinical findings and serological testing. West Nile virus RNA is usually negative by the time patients present with symptoms, unless the patient is immunocompromised. Improperly collected samples may result in false negative results. PCR assays may be impacted by viral variants and may result in reduced sensitivity or false negative results. This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.

LOINC map

Result codeResult nameUnitsResult LOINC
140243West Nile Virus RNA, Qual PCR34460-6

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 87798

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation