Diabetes Risk Index (DRI): Labcorp test 123855
Labcorp test 123855, CPT 81599. Specimen: Serum or plasma, shipped refrigerated. Turnaround: 2 - 3 days.
Use
The Diabetes Risk Index (DRI) is intended for use in adult subjects for the quantitative determination of a risk score in serum or plasma. The DRI score (1-100) may be used as an aid in stratifying the risk of developing type 2 diabetes in individuals with normo-glycemia or prediabetes.
Methodology
Nuclear magnetic resonance (NMR)
Collection instructions
Collect specimen in a lavender-top (EDTA-no gel) tube, which is the preferred specimen. For specimens collected in plain red-top tube, hold tube upright at room temperature for 45 minutes and allow to clot. Centrifuge specimen after clotting according to manufacturer's specifications. Transfer to a transport tube for storage at (2°C to 8°C) until shipped. For NMR LipoTube (black-and-yellow-top tube), keep upright at room temperature for 30 minutes and allow to clot. Centrifuge at 1600 to 1800 xg for 10 to 15 minutes immediately after clotting. If the sample cannot be centrifuged immediately, it must be refrigerated at (2°C to 8°C) and centrifuged within 24 hours of collection. The NMR tube should then be stored at (2°C to 8°C) until shipped. Do not open NMR LipoTube. Separate plasma from lavender-top (EDTA-no gel) tube or green-top (heparin-no gel) tube immediately after collection and transfer to a plastic transport tube for shipment to the laboratory. Serum or plasma drawn in gel-barrier collection tubes other than the NMR LipoTube should not be used.
Stability
| Temperature | Period |
|---|---|
| Refrigerated | 14 days |
| Frozen | 14 days |
| Freeze/thaw cycles | Stable x5 |
Patient preparation
Patient should be fasting for a minimum of eight to 12 hours.
Causes for rejection
Uncentrifuged NMR LipoTube or unseparated plain serum or EDTA plasma tube; serum or plasma specimen drawn in gel-barrier collection tube other than the NMR LipoTube; gross hemolysis; specimen more than 14 days post-collection
Reference range
Diabetes Risk Index (DRI) Cut Points Male Female Low risk: <50 <40 Intermediate risk: 50−65 40−55 High risk: >65 >55
Limitations
Measurements from plasma specimens are on average eight points lower than from serum specimens. Note: The results of the freeze/thaw study for the plain serum samples showed a 10% increase in DRI upon the first freeze/thaw cycle and no further changes upon successive freeze/thaw cycles. This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 123856 | Diabetes Risk Index (DRI) | 94560-0 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 81599
- 1st Trimester Preeclampsia Screen
- Hepatitis B Virus (HBV) FibroSure®
- Lipid Panel With Apolipoprotein B (ApoB), GlycA (Inflammation), Diabetes Risk Index (DRI)
- Lipid Panel With Diabetes Risk Index (DRI)
- Lipid Panel With GlycA (Inflammation) and Diabetes Risk Index (DRI)
- Liver Fibrosis, Chronic Viral Hepatitis
- Liver Fibrosis, Chronic Viral Hepatitis (Echosens FibroMeter)
- Liver Fibrosis, Non-Alcoholic Fatty Liver Disease (Echosens)
- Metabolic Vulnerability Index (MVX) by NMR
- Metabolic Vulnerability Index (MVX) Plus by NMR
- NIS2+
- 1st Trimester Preeclampsia Screen
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation