Thrombin Mixing Study: Labcorp test 117170
Labcorp test 117170, CPT 85670. Specimen: Plasma, frozen. Turnaround: 2 - 3 days.
Also known as: Thrombin Clotting Time (TCT)
Test includes
Thrombin time; reflex to thrombin time 1:1 mix and thrombin neutralization
Use
This test is used to help to determine the presence of an inhibitor.
Methodology
Human thrombin is mixed with the patient sample and clotting time is determined photometrically. When the thrombin time is extended, the test plasma is mixed 1:1 with normal platelet-free plasma and a TT is performed on the mixture. This serves to distinguish fibrinogen deficiency from something inhibiting fibrin polymerization. Heparin neutralization is also performed to rule out heparin as the cause of the extended TT.
Collection instructions
Citrated plasma samples should be collected by double centrifugation. Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples, except when using a winged blood collection device (ie, "butterfly"), in which case a discard tube should be used. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge for 10 minutes and carefully remove / 3 of the plasma using a plastic transfer pipette, being careful not to disturb the cells. Deliver to a plastic transport tube, cap, and recentrifuge for 10 minutes. Use a second plastic pipette to remove the plasma, staying clear of the platelets at the bottom of the tube. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
Patient preparation
Avoid warfarin (Coumadin®) therapy for two weeks and heparin therapy for two days prior to the test. Do not draw from an arm with a heparin lock or heparinized catheter.
Causes for rejection
Gross hemolysis; clotted specimen; frozen specimen thawed in transit; improper labeling
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 109009 | Thrombin Time | sec | 3243-3 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 85670
- Abnormal Bleeding Profile
- Antiphospholipid Syndrome (APS) Assessment
- Antiphospholipid Syndrome Reflex Panel
- Dilute Thrombin Time Panel
- Elevated PT and PTT Mixing Panel
- Fibrinogen Evaluation Profile
- Hypercoagulation Diagnostic Interpretive Panel
- Lupus Anticoagulant Diagnostic Interpretive Panel
- Lupus Anticoagulant Reflex Panel
- Prolonged Clot Time Reflexive Profile
- Thrombin Time
- Thrombin Time
- Thrombin Time with Reflex to Thrombin Time 1:1 Mix
- Thrombotic Risk Assessment
- Thrombotic Risk Reflex Panel
- Thrombotic Risk, Acquired