Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Thrombin Mixing Study

Thrombin Mixing Study: Labcorp test 117170

Labcorp test 117170, CPT 85670. Specimen: Plasma, frozen. Turnaround: 2 - 3 days.

Thrombin Mixing Study is Labcorp test code 117170, billed with CPT 85670. Specimen: Plasma, frozen. Turnaround time: 2 - 3 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code117170
CPT85670 If reflex testing is performed, concomitant CPT codes/charges will apply.
LOINC3243-3
SpecimenPlasma, frozen
Volume2 mL
Minimum volume1.0 mL ( Note: This volume does not allow for repeat testing.)
ContainerBlue-top (sodium citrate) tube
Turnaround time2 - 3 days
Storage / transportFreeze.

Also known as: Thrombin Clotting Time (TCT)

Test includes

Thrombin time; reflex to thrombin time 1:1 mix and thrombin neutralization

Use

This test is used to help to determine the presence of an inhibitor.

Methodology

Human thrombin is mixed with the patient sample and clotting time is determined photometrically. When the thrombin time is extended, the test plasma is mixed 1:1 with normal platelet-free plasma and a TT is performed on the mixture. This serves to distinguish fibrinogen deficiency from something inhibiting fibrin polymerization. Heparin neutralization is also performed to rule out heparin as the cause of the extended TT.

Collection instructions

Citrated plasma samples should be collected by double centrifugation. Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples, except when using a winged blood collection device (ie, "butterfly"), in which case a discard tube should be used. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge for 10 minutes and carefully remove / 3 of the plasma using a plastic transfer pipette, being careful not to disturb the cells. Deliver to a plastic transport tube, cap, and recentrifuge for 10 minutes. Use a second plastic pipette to remove the plasma, staying clear of the platelets at the bottom of the tube. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.

Patient preparation

Avoid warfarin (Coumadin®) therapy for two weeks and heparin therapy for two days prior to the test. Do not draw from an arm with a heparin lock or heparinized catheter.

Causes for rejection

Gross hemolysis; clotted specimen; frozen specimen thawed in transit; improper labeling

LOINC map

Result codeResult nameUnitsResult LOINC
109009Thrombin Timesec3243-3

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 85670

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.