Thrombin Time: Cleveland Clinic Laboratories test TT
Cleveland Clinic Laboratories test TT, CPT 85670. Specimen: Plasma. Turnaround: 4 hours.
Thrombin Time is Cleveland Clinic Laboratories test code TT, billed with CPT 85670. Specimen: Plasma. Turnaround time: 4 hours. Performing laboratory: Cleveland Clinic Laboratories, CLIA 36D0656094 (Cleveland, OH). Other labs in the directory with tests billed under the same CPT: Labcorp, ARUP Laboratories.
LaboratoryCleveland Clinic Laboratories
CLIA number36D0656094
Test codeTT
CPT85670 - QTY (1)
LOINC3243-3
SpecimenPlasma
Volume2 mL
Minimum volume0.5 mL
ContainerSodium citrate (Lt. Blue)
Turnaround time4 hours
Storage / transportFrozen
Methodology
Clotting Assay
Performed
Mon - Fri
Performing Laboratory
Cleveland Clinic Laboratories
View this test on Cleveland Clinic Laboratories's website → · Last checked 2026-11-29
Other tests billed with CPT 85670
- Abnormal Bleeding Profile
- Antiphospholipid Syndrome (APS) Assessment
- Antiphospholipid Syndrome Reflex Panel
- Dilute Thrombin Time Panel
- Elevated PT and PTT Mixing Panel
- Fibrinogen Evaluation Profile
- Hypercoagulation Diagnostic Interpretive Panel
- Lupus Anticoagulant Diagnostic Interpretive Panel
- Lupus Anticoagulant Reflex Panel
- Prolonged Clot Time Reflexive Profile
- Thrombin Mixing Study
- Thrombin Time
- Thrombin Time with Reflex to Thrombin Time 1:1 Mix
- Thrombotic Risk Assessment
- Thrombotic Risk Reflex Panel
- Thrombotic Risk, Acquired
Search the National Lab Test Directory · All Cleveland Clinic Laboratories tests and CLIA locations
Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation